EasyManua.ls Logo

Spectracom SecureSync - The Local System Reference

Spectracom SecureSync
599 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.
Click Submit.
Resetting Reference Priorities to Factory Defaults
To reset all references in the Reference Priority table to their factory default priorities:
1.
Navigate to the Configure Reference Priorities screen via MANAGEMENT > OTHER: Refer-
ence Priority menu.
2.
In the Actions panel, click the Restore Factory Defaults button.
3.3.1.2 The "Local System" Reference
The Local System reference is a "Self" reference, i.e. SecureSync uses itself as an input ref-
erence for Time, or as a 1PPS reference. The Local System is a unique input reference in that it
can be used as either the Time reference, or the 1PPS reference, but never both.
Note: For SecureSync to operate as a Local System reference, you must have
either a valid external Time reference, or a valid external 1PPS reference.
When the Time reference is configured as Local System, SecureSync's System Time is con-
sidered a valid reference, as long as the external 1PPS input reference is valid.
166
CHAPTER 3 SecureSync User Reference Guide Rev. 26
3.3 Managing References

Table of Contents

Related product manuals