Sanitization
The Delete Position command must also be used when sanitizing a SecureSync unit (ensuring that
no trace of position data remains on the unit). See "Sanitizing the Unit" on page329.
Deleting the GNSS position
To delete the GNSS position:
1.
Disconnect the GNSS antenna from the SecureSync unit (this is required only when san-
itizing the unit).
2.
Navigate to Interfaces > References: GNSS Reference.
3.
Click on the GEAR button next to the GNSS Reference (typically, there is only one ref-
erence, numbered "0"). The GNSS0 window will open:
Locate the Delete Position box, check it, and click Submit.
4.
SecureSync will initiate a GNSS self survey.
Note: In Mobile Receiver Mode it is NOT possible to delete the position and start
the GNSS survey. This feature is only available in Standard Mode and in Single
Satellite Mode. In Single Satellite Mode a GNSS survey may take up to 24 hours.
3.3.3.9 Manually Setting the GNSS Position
Note: This topic applies only to stationary applications, i.e. to Standard mode,
or Single Satellite mode.
The exact geographic position (location and elevation) of the antenna your SecureSync unit—
and thus its onboard GNSS receiver—is a major factor for SecureSync to calculate an accur-
ate System Time from the GNSS reference.
198
CHAPTER 3 SecureSync User Reference Guide Rev. 26
3.3 Managing References

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Spectracom SecureSync and is the answer not in the manual?

Spectracom SecureSync Specifications

General IconGeneral
ModelSecureSync
Time ReferenceGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
DisciplinesGNSS, IRIG, PTP, NTP, SyncE
InputsGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
OutputsNTP, PTP, 1PPS, IRIG
ProtocolsPTP, NTP, SNMP, SSH, HTTPS
Form Factor1U Rack-mount
RedundancyOptional redundant power supply
Security FeaturesPassword protection, access control lists, SSH, HTTPS, SNMPv3, NTP authentication, PTP authentication
Power Supply100-240 VAC, 50-60 Hz
Operating Temperature0°C to +50°C
Dimensions44.45 mm (H) x 482.6 mm (W)