EasyManuals Logo

Spectracom SecureSync User Manual

Spectracom SecureSync
599 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #546 background imageLoading...
Page #546 background image
5.4.10 Spectracom Format 7
This format provides a time data stream with millisecond resolution. The Format 7 data stream
consists of indicators for time synchronization status, leap second and Daylight Saving Time.
Time data reflects UTC time and is in the 24-hour format. Format 7 data structure is shown
below:
Note: Format 7 cannot be configured for a Time Zone Offset or with automatic
Daylight Saving Time adjustment. Attempting to configure a Local clock using
Data Format 7 with either a Time Zone Offset or automatic DST rule will result in
an error message.
E x a m p l e m e s s a g e :
CR LF I^YY^DDD^HH:MM:SS.SSSL^D CR LF
Where:
CR Carriage Return
LF Line Feed
I Time Sync Status (space, ?, *)
YY Year without century (99, 00, 01, etc.)
^ Space separator
DDD Day of Year (001-366)
HH Hours (00-23 UTC time)
: Colon separator
MM Minutes (00-59)
SS Seconds (00-60)
. Decimal Separator
SSS Milliseconds (000-999)
L Leap Second Indicator (space, L)
D Daylight Saving Time Indicator (S,I,D,O)
The leading edge of the first character (CR) marks the on-time point of the data stream.
The time synchronization status character (I) is defined as described below:
530 SecureSync User Reference Guide
APPENDIX

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Spectracom SecureSync and is the answer not in the manual?

Spectracom SecureSync Specifications

General IconGeneral
ModelSecureSync
Time ReferenceGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
DisciplinesGNSS, IRIG, PTP, NTP, SyncE
InputsGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
OutputsNTP, PTP, 1PPS, IRIG
ProtocolsPTP, NTP, SNMP, SSH, HTTPS
Form Factor1U Rack-mount
RedundancyOptional redundant power supply
Security FeaturesPassword protection, access control lists, SSH, HTTPS, SNMPv3, NTP authentication, PTP authentication
Power Supply100-240 VAC, 50-60 Hz
Operating Temperature0°C to +50°C
Dimensions44.45 mm (H) x 482.6 mm (W)