Alarm Type:
None: Will not output for an alarm.
Minor: Will output on a minor alarm.
Major: Will output on a major alarm.
5.2.7.4 Revertive Selector Card [1204-2E]
The Revertive Selector Option Card provides automatic failover capability, using one option
card slot for a single output signal.
Operating Principle
The output follows the selected input. Signals can be 1PPS, 10MHz, 5MHz or 1MHz.
Input “A is selected if present and valid. If input “A disappears, or if power to host
SecureSync is interrupted, input B is presented at output “OUT”.
As soon as input A becomes valid again, the output switches back to use A” as source.
At power-up or module reset, there is a timed delay before input “A is presented. This allows
reference at input “A to stabilize before being used.
Model 1204-2E Specifications
Inputs/Outputs:
(2) Inputs Unselected input terminated with 50Ω
(1) Output
Connectors: 3 BNC
Signal Type: User selected (jumper switch):
>1MHz
1MHz to 100Hz
1PPS
Signal Level:
Sine Wave, 0.5V to 30V
p-p
TTL (50 )
Default Power-on Switch State:
Initially, input “B; until a valid signal on input "A" is detected, causing the switch state to
change to "A".
500 SecureSync User Reference Guide