Downloading Temperature Data
It is possible to download the temperature data e.g., to plot your own temperature graphs, or
because Spectracom Technical Support inquires about this data for diagnostic purposes in the
event of technical problems.
To download the logged data used to generate the displayed graphs, navigate to any
panel that displays one or more graphs (see above), and click on the Arrow icon in the
top-right corner.
A file named systemMonitorLog.csv file will be generated in your designated down-
load folder.
Deleting Temperature Data
Temperature graphs (and other graphs as well) will display up to approximately 10000 read-
ings, which are generated at a 1/min. rate, i.e. the data displayed covers about 7days. There-
after, the oldest data gets overwritten.
To delete the logged data used to generate the displayed graphs, click the TRASH CAN
icon in the top-right corner of the panel.
Note that re-populating the graphs with fresh data will take several minutes.
Temperature Readout via CLI
Temperature data can be read out via the CLI using the i2cget command:
E X A M P L E :
i2cget -y 0 0x4d <register>
i2cget returns temperature in Celsius in hex format. No
additional conversion required.
Further reading
See also: "Troubleshooting the Front Panel Cooling Fan" on page343.
4.5.2 Logs
SecureSync maintains different types of event logs (see below) to allow for traceability, and for
record keeping. Should you ever require technical support from Spectracom, you may be
asked for a copy of your logs to facilitate remote diagnosis.
Logs stored internally are being kept automatically, while the storage of log files in a remote
location has to be set up by the user.
For each type of log, four 75KB files are maintained internally on a revolving basis, i.e. the
oldest file will be overwritten, as soon as all four files have filled up with event data. The life
expectancy of a log file depends on the amount of data accumulating over time: Some types of
logs will fill up within days, while others can take months until they have reached their max-
imum storage capacity.
4.5 Quality Management
CHAPTER 4 SecureSync User Reference Guide Rev. 26
303

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Spectracom SecureSync and is the answer not in the manual?

Spectracom SecureSync Specifications

General IconGeneral
ModelSecureSync
Time ReferenceGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
DisciplinesGNSS, IRIG, PTP, NTP, SyncE
InputsGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
OutputsNTP, PTP, 1PPS, IRIG
ProtocolsPTP, NTP, SNMP, SSH, HTTPS
Form Factor1U Rack-mount
RedundancyOptional redundant power supply
Security FeaturesPassword protection, access control lists, SSH, HTTPS, SNMPv3, NTP authentication, PTP authentication
Power Supply100-240 VAC, 50-60 Hz
Operating Temperature0°C to +50°C
Dimensions44.45 mm (H) x 482.6 mm (W)

Related product manuals