Note: The Delete button in the Edit Leap Second window will only be visible if a
leap second has been set beforehand.
3.2.4 Local Clock(s), DST
The Local Clock feature allows for maintaining one or several local times. These times will reflect
a time offset, thereby accounting for Time Zone, and DST (Daylight Savings Time) correction.
3.2.4.1 Adding a Local Clock
To add a Local Clock:
1.
Navigate to MANAGEMENT > OTHER: Time Management.
2.
Click the PLUS icon in the Local Clocks panel in the Time Management screen.
3.
The Local Clock pop-up window will display.
4.
Enter a Name for your local clock.
The name must be between 1 and 64 characters long; spaces are allowed.
The name can be any meaningful name that helps you know your point of ref-
erence (for example: NewYork”, “Paris” or “EasternHQ”, etc.).
This name will be used as cross-reference drop-down in the applicable Input or
Output port configuration. Please note the following limitations apply to this
option:
Note: Acceptable characters for the name include: A-Z, a-z, 0-9, (-
+_) and space.
158
CHAPTER 3 SecureSync User Reference Guide Rev. 26
3.2 System Time

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Spectracom SecureSync and is the answer not in the manual?

Spectracom SecureSync Specifications

General IconGeneral
ModelSecureSync
Time ReferenceGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
DisciplinesGNSS, IRIG, PTP, NTP, SyncE
InputsGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
OutputsNTP, PTP, 1PPS, IRIG
ProtocolsPTP, NTP, SNMP, SSH, HTTPS
Form Factor1U Rack-mount
RedundancyOptional redundant power supply
Security FeaturesPassword protection, access control lists, SSH, HTTPS, SNMPv3, NTP authentication, PTP authentication
Power Supply100-240 VAC, 50-60 Hz
Operating Temperature0°C to +50°C
Dimensions44.45 mm (H) x 482.6 mm (W)

Related product manuals