Feature Default Setting Recommended Setting
Where to
Configure
SNMP Enabled Disabled or Enabled (with SNMP v3 w/
encryption*)
WebUI
NTP Enabled (with no MD5 values entered) Enabled (use MD5 authentication with
user-defined keys)
WebUI
Daytime
Protocol
Disabled Disabled WebUI
Time
Protocol
Disabled Disabled WebUI
Command Line Interface
Serial
Port
Available Available n/a
Telnet Enabled Disabled (use SSH instead) Web UI
SSH Enabled (default private keys provided) Enabled Web UI
File Transfer
FTP Enabled Disabled (use SFTP or SCP) Web UI
SCP Available Disabled (use SFTP or SCP) Web UI
SFTP Available Disabled (use SFTP or SCP) Web UI
*Spectracom recommends that secure clients use only SNMPv3 with authentication for secure
installations.
4.7.5 Sanitizing the Unit
The concept of sanitizing a SecureSync unit refers to erasing usage data that may be stored in
volatile and/or non-volatile memory, i.e. permanently eliminating any data that could be used
to trace the unit's former usage. This data may include but is not limited to logs, con-
figuration settings, IPaddresses, passwords, GNSS geographic positioning data, and network-
specific usage data.
From a top level, cleaning a SecureSync involves restoring the following to factory default con-
figurations:
1.
The file system on the Compact Flash (CF) card is restored to factory state by removing
the logs and restoring all configuration files to the default factory state.
2.
Commercial GPS/GNSS receivers have stored position data deleted, and are setup to
resurvey on reboot.
The command line gpsreset clean option erases the GPS/GNSS receiver flash
memory, returning it to factory state and setting up to resurvey.
4.7 Resetting the Unit to Factory Configuration
CHAPTER 4 SecureSync User Reference Guide Rev. 26
329

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Spectracom SecureSync and is the answer not in the manual?

Spectracom SecureSync Specifications

General IconGeneral
ModelSecureSync
Time ReferenceGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
DisciplinesGNSS, IRIG, PTP, NTP, SyncE
InputsGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
OutputsNTP, PTP, 1PPS, IRIG
ProtocolsPTP, NTP, SNMP, SSH, HTTPS
Form Factor1U Rack-mount
RedundancyOptional redundant power supply
Security FeaturesPassword protection, access control lists, SSH, HTTPS, SNMPv3, NTP authentication, PTP authentication
Power Supply100-240 VAC, 50-60 Hz
Operating Temperature0°C to +50°C
Dimensions44.45 mm (H) x 482.6 mm (W)