Note: Whether or not notifications are enabled/disabled for a given event, the
occurrence of the event is always logged.
All available SecureSync events that can generate a notification to be sent are located under
different tabs in the Notification Events panel: Timing, GPS, and System.
The SecureSync Events that can automatically trigger a notification are listed in the Event
column. It is possible to:
Mask the alarm generation for specific events (prevent the alarm)
Enable “SNMP” (to send out an SNMP trap)
Send an email to the address specified in the corresponding “Email Address column.
4.2.1 Configuring Notifications
To configure Notifications:
1.
Navigate to MANAGEMENT > OTHER: Notifications. The Notifications screen will display:
It is divided into two panels:
The Actions panel, featuring:
The SNMP Setup button: See "SNMP" on page84.
The Email Setup button: Configure SecureSync's interface settings for
Exchange email servers and Gmail.
For more information on this subject, see the Spectracom Technical Note
Email Notification Setup.
The Events panel, offering three tabs:
Timing: Events for Sync Status and Holdover, Frequency error, Input ref-
erences and the internal oscillator.
240
CHAPTER 4 SecureSync User Reference Guide Rev. 26
4.2 Notifications

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Spectracom SecureSync and is the answer not in the manual?

Spectracom SecureSync Specifications

General IconGeneral
ModelSecureSync
Time ReferenceGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
DisciplinesGNSS, IRIG, PTP, NTP, SyncE
InputsGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
OutputsNTP, PTP, 1PPS, IRIG
ProtocolsPTP, NTP, SNMP, SSH, HTTPS
Form Factor1U Rack-mount
RedundancyOptional redundant power supply
Security FeaturesPassword protection, access control lists, SSH, HTTPS, SNMPv3, NTP authentication, PTP authentication
Power Supply100-240 VAC, 50-60 Hz
Operating Temperature0°C to +50°C
Dimensions44.45 mm (H) x 482.6 mm (W)