003.1,W Magnetic Variation
*6A Checksum data, always begins with *
5.4.3 NMEA ZDA Message
The Format ZDA Data message provides Date and Time information.
E x a m p l e m e s s a g e :
$GPZDA,HHMMSS.00,DD,MM,YYYY,XX,YY*CC
Where:
HHMMSS.00 HrMinSec(UTC)
DD,MM,YYYY Day, Month, Year
XX Local zone hours -13…13
YY Local zone minutes 0…59
*CC Checksum
5.4.4 Spectracom Format 0
Format 0 includes a time synchronization status character, day of year, time reflecting Time
Zone Offset and DST corrections when enabled. Format 0 also includes the DST/Standard Time
indicator, and the Time Zone Offset value. Format 0 data structure is shown below:
E x a m p l e m e s s a g e :
CR LF I ^ ^ DDD ^ HH:MM:SS ^ DTZ=XX CR LF
Where:
CR Carriage Return
LF Line Feed
I Time Sync Status (space, ?, *)
^ Space separator
DDD Day of Year (001-366)
HH Hours (00-23)
520 SecureSync User Reference Guide
APPENDIX

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Spectracom SecureSync and is the answer not in the manual?

Spectracom SecureSync Specifications

General IconGeneral
ModelSecureSync
Time ReferenceGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
DisciplinesGNSS, IRIG, PTP, NTP, SyncE
InputsGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
OutputsNTP, PTP, 1PPS, IRIG
ProtocolsPTP, NTP, SNMP, SSH, HTTPS
Form Factor1U Rack-mount
RedundancyOptional redundant power supply
Security FeaturesPassword protection, access control lists, SSH, HTTPS, SNMPv3, NTP authentication, PTP authentication
Power Supply100-240 VAC, 50-60 Hz
Operating Temperature0°C to +50°C
Dimensions44.45 mm (H) x 482.6 mm (W)