4.5.2.9 Clearing All Logs
Note: Authentication logs and NTP logs cannot be cleared.
All local logs in the home/spectracom directory will be logged. Other logs e.g., located
on Syslog Servers, must be maintained by the user.
To clear all locally stored log files:
1.
Navigate to MANAGEMENT > OTHER: Log Configuration.
2.
In the Actions panel, click Clear All Logs:
3.
In the grey confirmation window, click OK.
4.5.2.10 Clearing Selected Logs
Note: NTP logs cannot be cleared.
To clear selected locally stored log files:
1.
Navigate to MANAGEMENT > OTHER: Log Configuration.
2.
In the Logs panel, click the X-icon next to the log category you wish to clear (e.g., Alarms
log).
3.
In the grey confirmation box, click OK.
318
CHAPTER 4 SecureSync User Reference Guide Rev. 26
4.5 Quality Management

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Spectracom SecureSync and is the answer not in the manual?

Spectracom SecureSync Specifications

General IconGeneral
ModelSecureSync
Time ReferenceGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
DisciplinesGNSS, IRIG, PTP, NTP, SyncE
InputsGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
OutputsNTP, PTP, 1PPS, IRIG
ProtocolsPTP, NTP, SNMP, SSH, HTTPS
Form Factor1U Rack-mount
RedundancyOptional redundant power supply
Security FeaturesPassword protection, access control lists, SSH, HTTPS, SNMPv3, NTP authentication, PTP authentication
Power Supply100-240 VAC, 50-60 Hz
Operating Temperature0°C to +50°C
Dimensions44.45 mm (H) x 482.6 mm (W)