Web UI Page Current Status Indication Troubleshooting
Navigate to
INTERFACES/OUTPUTS/
PPS Output page
Select the PPS
Output screen.
See "The Out-
puts Screen"
on page137.
Signature Con-
trol will show
"Output Always
Enabled",
"Output Enabled
in Holdover",
"Output Dis-
abled in Hol-
dover" or
"Output Always
Disabled".
1. With "Output Always Enabled"
selected, the selected output will be
present no matter the current syn-
chronization state.2. Any other con-
figured value will cause the applicable
output to be halted if SecureSync is not
fully synchronized with its input ref-
erences.
Table 5-4:
Troubleshooting 1PPS and/or 10 MHz outputs not being present
5.1.9 Troubleshooting Blank Information Display
If the front panel 4-line LCD Information Display is blank:
As long as input power is applied (as indicated by the power light being green and the LED
time display incrementing) the 4-line LCD Information Display is capable of displaying data.
The Information Display can be configured to display different data while the keypad is not in
use. One available configuration is to have the Information Display show a blank page when
not in use. The Information Display operation can be verified and can also be configured via
the Web UI, or the front panel keypad.
A.
Using the front panel keypad to verify the LCD Information Display is configured to display a
blank page:
To verify the front panel LCD Information Display is configured to display a blank page,
just press any keypad button. As long as the keypad is unlocked, the Home screen will
be displayed (after one minute of not pushing any keys, the screen will go back to
blank).
Note: The information that is selected, is the page that is normally displayed in the
LCD window, beginning one minute after the keypad is no longer being used.
B.
Using the front panel keypad to change the information normally displayed in the LCD when
the keypad is not in use:
342 SecureSync User Reference Guide
APPENDIX

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Spectracom SecureSync and is the answer not in the manual?

Spectracom SecureSync Specifications

General IconGeneral
ModelSecureSync
Time ReferenceGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
DisciplinesGNSS, IRIG, PTP, NTP, SyncE
InputsGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
OutputsNTP, PTP, 1PPS, IRIG
ProtocolsPTP, NTP, SNMP, SSH, HTTPS
Form Factor1U Rack-mount
RedundancyOptional redundant power supply
Security FeaturesPassword protection, access control lists, SSH, HTTPS, SNMPv3, NTP authentication, PTP authentication
Power Supply100-240 VAC, 50-60 Hz
Operating Temperature0°C to +50°C
Dimensions44.45 mm (H) x 482.6 mm (W)