4.5.2.6 Configuring Logs
Note: The NTP log has no available configuration options.
To configure a log:
1.
Navigate to MANAGEMENT > OTHER: Log Configuration.
2.
In the Logs panel select the log category you wish to configure e.g., System, then click the
PENCIL button next to it.
3.
In the Log File window, fill in the available fields (see below for explanations).
4.
Click Submit.
The following log configuration options are available:
a.
Add/Remove Remote Server: The Syslog server(s) to which remote logs are sent. This
panel is only available if Remote Log is checked below in the Log Configuration panel. If
the log has a remote log server to which it writes, the name of the server will appear
here. Click Delete to remove the remote server.
4.5 Quality Management
CHAPTER 4 SecureSync User Reference Guide Rev. 26
313

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Spectracom SecureSync and is the answer not in the manual?

Spectracom SecureSync Specifications

General IconGeneral
ModelSecureSync
Time ReferenceGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
DisciplinesGNSS, IRIG, PTP, NTP, SyncE
InputsGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
OutputsNTP, PTP, 1PPS, IRIG
ProtocolsPTP, NTP, SNMP, SSH, HTTPS
Form Factor1U Rack-mount
RedundancyOptional redundant power supply
Security FeaturesPassword protection, access control lists, SSH, HTTPS, SNMPv3, NTP authentication, PTP authentication
Power Supply100-240 VAC, 50-60 Hz
Operating Temperature0°C to +50°C
Dimensions44.45 mm (H) x 482.6 mm (W)