ATC: ASCII time code reference
USER: User provided time
LOCL: Local reference (synced to itself)
INIT: NTP on server/peer is initializing
STEP: NTP on server/peer is performing initial synchronization step and restart-
ing
AUTH STATUS: Indicates if the selected reference is using MD5 authentication. None”
indicates authentication not being used.
LAST: The number of seconds that have expired since this reference was last polled for its
time.
POLL: The polling interval, i.e. how often SecureSync is polling this NTP reference for its
time.
DELAY (ms): The measured one-way delay between SecureSync and its selected ref-
erence.
2.14.8.2 NTP Servers: Adding, Configuring, Removing
To add, configure, or remove an NTP Server:
1.
Navigate to MANAGEMENT > NETWORK: NTP Setup.
2.14 Configuring NTP
CHAPTER 2 SecureSync User Reference Guide Rev. 26
107

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Spectracom SecureSync and is the answer not in the manual?

Spectracom SecureSync Specifications

General IconGeneral
ModelSecureSync
Time ReferenceGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
DisciplinesGNSS, IRIG, PTP, NTP, SyncE
InputsGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
OutputsNTP, PTP, 1PPS, IRIG
ProtocolsPTP, NTP, SNMP, SSH, HTTPS
Form Factor1U Rack-mount
RedundancyOptional redundant power supply
Security FeaturesPassword protection, access control lists, SSH, HTTPS, SNMPv3, NTP authentication, PTP authentication
Power Supply100-240 VAC, 50-60 Hz
Operating Temperature0°C to +50°C
Dimensions44.45 mm (H) x 482.6 mm (W)