ATC: ASCII time code reference
USER: User provided time
LOCL: Local reference (synced to itself)
INIT: NTP on server/peer is initializing
STEP: NTP on server/peer is performing initial synchronization step and restart-
ing
AUTH STATUS: Indicates if the selected reference is using MD5 authentication. None”
indicates authentication not being used.
LAST: The number of seconds that have expired since this reference was last polled for its
time.
POLL: The polling interval, i.e. how often SecureSync is polling this NTP reference for its
time.
DELAY (ms): The measured one-way delay between SecureSync and its selected ref-
erence.
2.14.8.2 NTP Servers: Adding, Configuring, Removing
To add, configure, or remove an NTP Server:
1.
Navigate to MANAGEMENT > NETWORK: NTP Setup.
2.14 Configuring NTP