To EDIT an existing key pair, click the corresponding Change button, and pro-
ceed to Step4.
To DELETE a key pair, click the corresponding Delete button, and click OK in the
dialog box to confirm and complete the procedure.
4.
The NTP Symmetric Key window will display:
Fill in, or edit the fields:
Trusted (checkbox)Check this box to use MD5 authentication with trusted key ID.
Note: To use the MD5 authentication with trusted key ID, both the
NTP client and the SecureSync must contain the same key ID/key
string pair, the client must be set to use one of these MD5 pairs, and
the key must be trusted.
Key IDThe key ID must be a number between 1 and 65532.
Digest Scheme—Choose one of the options from the drop-down list. The available
options are:
MD5 (the default)
SHA1
SHA
MDC2
MDC2
RIPEMD160
MD4
Key StrThe key string must be readable ASCII and between 1 and 16 characters
long.
5.
Click the Submit button: The changes will be reflected in the table of the NTP Symmetric
Keys window, which is displayed after clicking the Submit button.
118
CHAPTER 2 SecureSync User Reference Guide Rev. 26
2.14 Configuring NTP

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Spectracom SecureSync and is the answer not in the manual?

Spectracom SecureSync Specifications

General IconGeneral
ModelSecureSync
Time ReferenceGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
DisciplinesGNSS, IRIG, PTP, NTP, SyncE
InputsGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
OutputsNTP, PTP, 1PPS, IRIG
ProtocolsPTP, NTP, SNMP, SSH, HTTPS
Form Factor1U Rack-mount
RedundancyOptional redundant power supply
Security FeaturesPassword protection, access control lists, SSH, HTTPS, SNMPv3, NTP authentication, PTP authentication
Power Supply100-240 VAC, 50-60 Hz
Operating Temperature0°C to +50°C
Dimensions44.45 mm (H) x 482.6 mm (W)