Note: If synchronization to UTC is NOT required, it is advisable to set a time in
the past or future, so as to avoid users inadvertently considering the distributed
time to be genuine.
Caution: Note that this mode of operation is intended for special use cases e.g.,
autonomous systems, where legally traceable time is not required: This time will
be inaccurate/not traceable, since it is not tied to any reference.
To hand-set the System Time, and configure this time to be a valid reference:
1.
Navigate to MANAGEMENT > OTHER: Time Management.
2.
In the System Time panel on the left, click the GEAR icon.
3.
Select Manual Time Set. Set your time & date, as needed:
System Time [DATE; TIME]: If you do not select Set Year Only, this box will show the
current time in the format: Year-Month-Day Hour:Minute:Second. To
set the time manually, click anywhere in the System Time field. A drop-down cal-
endar with time-setting sliders will appear:
The time in the System Time field will default to the current date and time. To set
the time, use the sliders. The time will display between the calendar and the
sliders, and also next to the chosen date in the field directly above the calendar.
To close the calendar, click anywhere in the Edit System Time window.
NOTE: Except for testing purposes, you should not choose a date other than the
current day.
Set Year Only: Some legacy time formats (e.g., IRIG) do not support years. Check-
ing this box will open a data entry field to manually set the year. Spectracom
3.2 System Time
CHAPTER 3 SecureSync User Reference Guide Rev. 26
151

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Spectracom SecureSync and is the answer not in the manual?

Spectracom SecureSync Specifications

General IconGeneral
ModelSecureSync
Time ReferenceGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
DisciplinesGNSS, IRIG, PTP, NTP, SyncE
InputsGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
OutputsNTP, PTP, 1PPS, IRIG
ProtocolsPTP, NTP, SNMP, SSH, HTTPS
Form Factor1U Rack-mount
RedundancyOptional redundant power supply
Security FeaturesPassword protection, access control lists, SSH, HTTPS, SNMPv3, NTP authentication, PTP authentication
Power Supply100-240 VAC, 50-60 Hz
Operating Temperature0°C to +50°C
Dimensions44.45 mm (H) x 482.6 mm (W)

Related product manuals