transitioning into Holdover, in case a reference becomes unavailable or invalid. The priority
order you assign to your available references typically is a function of their accuracy and reli-
ability.
Note: The References shown on your screen may look different from the ones in
the illustration below, depending on your SecureSync Time and Frequency Syn-
chronization System model and hardware configuration.
Each available type of Time and 1PPS input reference is assigned a human-readable name or
“title” that is used in the Reference Priority table, indicating the type of reference. The reference
titles are listed in the following table:
Table 3-1:
Reference priority titles
Title Reference
ASCII Timecode ASCII serial timecode input
External 1PPS input External 1PPS input
Frequency External Frequency input
GNSS GNSS input
PTP PTP input
IRIG IRIG timecode input
Local System Built-in clock OR internal 1PPS generation
NTP NTP input
User Host (time is manually set by the user)
HAVEQUICK HAVEQUICK input
162
CHAPTER 3 SecureSync User Reference Guide Rev. 26
3.3 Managing References

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Spectracom SecureSync and is the answer not in the manual?

Spectracom SecureSync Specifications

General IconGeneral
ModelSecureSync
Time ReferenceGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
DisciplinesGNSS, IRIG, PTP, NTP, SyncE
InputsGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
OutputsNTP, PTP, 1PPS, IRIG
ProtocolsPTP, NTP, SNMP, SSH, HTTPS
Form Factor1U Rack-mount
RedundancyOptional redundant power supply
Security FeaturesPassword protection, access control lists, SSH, HTTPS, SNMPv3, NTP authentication, PTP authentication
Power Supply100-240 VAC, 50-60 Hz
Operating Temperature0°C to +50°C