EasyManuals Logo

Spectracom SecureSync User Manual

Spectracom SecureSync
599 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #243 background imageLoading...
Page #243 background image
a): ADDING a PTP Slave
To add and configure a new PTP Slave:
1.
Navigate to PTP Setup screen via MANAGEMENT > NETWORK > PTP Setup.
2.
In the PTP Slaves panel, click the PLUS icon in the top right corner.
3.
The Add Source pop-up window displays. Fill in the applicable parameter values:
PTP Client Version: Ver.1 or Ver.2
PTP Server: The address of the PTP server (this field will be populated by
TimeKeeper, if only one server has been configured).
PTP Domain: Determines which domain the PTP server will broadcast on. [Range:
0-255; default-suggested domain for PTP1: 0]
Low Quality Source: Check this box to improve tracking of low quality sources,
such as NTPd. [Default: Checked]
Unicast Delay Requests: Enables unicast delay requests back to the server. Check
this box if you would like the PTP Master to provide unicast delay responses, no
matter if the client provided a unicast or a multicast delay request. When the box
is unchecked, the server will respond with the same type of message as the
request, that is a multicast response for a multicast request, and a unicast response
for a unicast request. [Recommended setting: Unchecked]
Use Transparent Clock Corrections: Check to allow the slave to apply the trans-
parent clock correction provided with PTP data. [Default: Checked]
3.6 Managing TimeKeeper
CHAPTER 3 SecureSync User Reference Guide Rev. 26
227

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Spectracom SecureSync and is the answer not in the manual?

Spectracom SecureSync Specifications

General IconGeneral
ModelSecureSync
Time ReferenceGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
DisciplinesGNSS, IRIG, PTP, NTP, SyncE
InputsGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
OutputsNTP, PTP, 1PPS, IRIG
ProtocolsPTP, NTP, SNMP, SSH, HTTPS
Form Factor1U Rack-mount
RedundancyOptional redundant power supply
Security FeaturesPassword protection, access control lists, SSH, HTTPS, SNMPv3, NTP authentication, PTP authentication
Power Supply100-240 VAC, 50-60 Hz
Operating Temperature0°C to +50°C
Dimensions44.45 mm (H) x 482.6 mm (W)