i.
The "administrator" account (spadmin), and
ii.
The "factory" service account (spfactory).
Additional accounts may be added and deleted as desired. The number of accounts that can
be setup is virtually unlimited.
Note: The password for the spadmin account can be changed (and it is recom-
mended to do so for security reasons). However, the spadmin account name
cannot be changed, and the account cannot be removed from SecureSync.
Note: The spfactory account is for use by Spectracom service personnel.
While the spfactory account can be deleted by an administrator, it should
be noted that this may potentially limit remotely provided technical support.
User accounts can be created to have either limited user or full administrator rights. Each user
can be assigned his own login password.
To ADD a user account, click the PLUS icon in the top-right corner of the Users screen.
To DELETE a user account, click the Delete button in that account’s entry on the Users
screen.
To APPLY CHANGES to a user account, click the Change button next to the desired user
account.
When either the Change button or the PLUS icon is clicked, the Add or Change User window
appears:
To add a user account:
1.
Enter a Username. (For rules, see "Rules for Usernames" on the previous page.)
250
CHAPTER 4 SecureSync User Reference Guide Rev. 26
4.3 Managing Users and Security

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Spectracom SecureSync and is the answer not in the manual?

Spectracom SecureSync Specifications

General IconGeneral
ModelSecureSync
Time ReferenceGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
DisciplinesGNSS, IRIG, PTP, NTP, SyncE
InputsGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
OutputsNTP, PTP, 1PPS, IRIG
ProtocolsPTP, NTP, SNMP, SSH, HTTPS
Form Factor1U Rack-mount
RedundancyOptional redundant power supply
Security FeaturesPassword protection, access control lists, SSH, HTTPS, SNMPv3, NTP authentication, PTP authentication
Power Supply100-240 VAC, 50-60 Hz
Operating Temperature0°C to +50°C