3.
Fill out the fields:
Host: The hostname or IP address of the RADIUS server
Port: Defines the RADIUS Port to use. The default RADIUS Port is 1812, but this can
be changed, as required.
Secret Key: The secret key which is shared by SecureSync and the RADIUS server
(the key is used to generate an MD5 hash).
Timeout: [seconds] Defines the Timeout that SecureSync will wait to communicate
with the RADIUS server e.g., 10 seconds.
4.
Click the Add Server button. A confirmation message The item has been added will be dis-
played if the server could be added, and the server will be added to the list, indicating
its status. The server status can be:
DISABLED: RADIUS service is disabled.
UNREACHABLE: This RADIUS server cannot be reached.
REACHABLE: This RADIUS server can be reached.
5.
To remove a RADIUS server from the list, click the X-button in the Actions column.
Note: SecureSync supports multiple RADIUS servers. The system performance, how-
ever, will be negatively affected by a large number of servers or invalid servers,
respectively.
264
CHAPTER 4 SecureSync User Reference Guide Rev. 26
4.3 Managing Users and Security

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Spectracom SecureSync and is the answer not in the manual?

Spectracom SecureSync Specifications

General IconGeneral
ModelSecureSync
Time ReferenceGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
DisciplinesGNSS, IRIG, PTP, NTP, SyncE
InputsGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
OutputsNTP, PTP, 1PPS, IRIG
ProtocolsPTP, NTP, SNMP, SSH, HTTPS
Form Factor1U Rack-mount
RedundancyOptional redundant power supply
Security FeaturesPassword protection, access control lists, SSH, HTTPS, SNMPv3, NTP authentication, PTP authentication
Power Supply100-240 VAC, 50-60 Hz
Operating Temperature0°C to +50°C
Dimensions44.45 mm (H) x 482.6 mm (W)