Ethernet Status: Whether the module is connected to a network through Ethernet.
Green=Connected. The speed of the connection is indicated.
Orange=Not connected.
Port State: Reports the current state of the PTP State Machine:
Disabled: PTP Ethernet port is Disabled. See PTP Setup/Network page, PTP Net-
work Settings options.
Initializing: Ethernet link is unplugged/PTP Module is in power-up state. A Master
Clock doesn’t leave this state while it can’t get the current time and syn-
chronization references from the SecureSync to synchronize with it.
Listening: PTP module is looking for a Master Clock.
Master: PTP Master has become the active Master Clock on the network.
Passive: PTP Module has become a Passive Master Clock. (There is another
Master Clock on the network with better quality or higher priority). This Master
will wait until the Best Master Clock Algorithm determines it should become the
best Master Clock, and then it will transition to the Master Clock state.
Uncalibrated: PTP Slave has selected a Master Clock on the network attempts to
synchronize with it using sync packets.
Number of Unicast Slaves: Number of PTP Slaves that have been granted by the PTP
Master to run in unicast mode (maximum = 4000 unicast contracts)
Profile: Whether the profile is the default or Telecom.
Domain Number: The current PTP Domain Number.
Clock Mode: See "Main tab settings" on page472.
Current IP Address: The IP address currently being used by the PTP interface.
MAC Address: The MAC address currently being used by the PTP interface.
Advanced tab: Status information
Time Properties:
UTC Offset: The Master’s current offset between UTC time and TAI time. Units: seconds.
UTC Offset Valid: Indicates whether or not the Master’s UTC Offset is valid.
Leap Second: The Leap second correction as set on the Time Management page.
Time Traceable: Indicates whether the Master’s time is traceable (Enabled) to a primary
reference or not (Disabled).
SecureSync User Reference Guide 477
APPENDIX