4 Teaching
4.8 Local Variables
4-64
HW1485509
HW1485509
4.8.1 Local Variable
4.8.1.1 Allocation
Local Variables need to be configured at first to be used.
1. Select {Job List} under {MENU}.
2. Select the particular job from the list of job.
3. Press the {Additional Settings} expansion icon at the bottom of the Job
Details panel.
This will pull up a new panel for Additional Settings.
4. Under the {Local Variable Allocation}, enter a number between 0 and 255
for the amount of variable to allocate, next to the desired variable type.
Example: the figure shows allocating 10 Local Byte (LB) variables.
Thus, LB000 to LB009 will be usable inside the job.