12.4.3.3 Safety Board Flash Reset
If the following alarms occur when control power is turned ON, perform the
following operations to reset the data of the safety circuit board and PFL
circuit board.
• Alarm 0300: “VERIFY ERROR (SYSTEM CONFIG-DATA) [10]”
• Alarm 0300: “VERIFY ERROR (SYSTEM CONFIG-DATA) [13]”
The Safety Board Flash Reset can only be performed in maintenance
mode.
1. In the Start Window (close the software and restart, if software pendant
is already connected to the YRC Controller), select the “Special
Mode”, and click “Maintenance Mode”.
2. Select {SYSTEM} under the Main Menu, and then select {SECURITY}
to change the security mode to the safety mode.