11 Safety Function
11.3 Safety Logic Circuit
11-18
HW1485509
HW1485509
11.3.3.4 Edit Input Relays
Press the input relay to edit.
Detail of the input relay will be shown on the detail panel.
If {Input Type} is pressed, the type of the input relay can be changed.
To select “Detect OFF
ON” or “Detect ONOFF”, the number of Input
relay should be 2 or less.
If {Signal} is pressed, the input signal can be changed. Refer to
chapter 11.3.2 for list of available signals and their meanings.
If {Name} is pressed, the name of the signal can be edited. The name
of the signal is also shown in the line of the Safety Logic Circuit. The name
of the signal also can be edited in the Signal Setting screen. The name of
signals which is not shown in the Signal Setting screen cannot be edited.
Input type can be selected from table 11-5.