11 Safety Function
11.3 Safety Logic Circuit
11-20
HW1485509
HW1485509
11.3.3.5 Edit Output Relays
Press output relay to edit.
Detail of the output relay will be shown on the detail panel.
If {Output Type} is pressed, the type of the output relay can be
changed. To select “Pulse”, the number of Input relay should be two or
less.
Timer number for the output relay can be changed. This item will be
shown when the output type is “Pulse”, “ON Delay”, or “OFF Delay”. The
same timer number cannot be used on multiple lines.
Specifies the timer value. Timer value should be multiple of 4. If the
input value is not multiple of 4, the value will be changed to multiple of 4.
This value can be changed in Timer Setting screen.
If {Signal} is pressed, the input signal can be changed. The same
output signal cannot be set to the multiple line. Refer to chapter 11.3.2 for
list of available signals and their meanings.
If {Name} is pressed, the name of the signal can be edited. The name
of the signal is also shown in the line of the Safety Logic Circuit. The
name of the signal also can be edited in the Signal Setting screen. The
name of signals which is not shown in the Signal Setting screen cannot be
edited.
NOTE
To use “Detect OFFON” or “Detect ONOFF” for Input
relay, Output relay should be “Pulse”. Also, to use “Pulse”
for Output relay, one of the input relay should be “Detect
OFF
ON” or “Detect ONOFF”.
Number of Input relay should be two or less.
1
4 5
2 3
1
2
3
4
5
352 of 493