11 Safety Function
11.3 Safety Logic Circuit
11-21
HW1485509
HW1485509
Table 11-6: Output Types
No. Display Contents
1 Output signal.
When there is a path of
CLOSED (ACTIVE) signals
connecting the left side to this
output then this expression is
CLOSED (ACTIVE).
2 Pulse
Output signal with a single
pulse.
When there is a path of
CLOSED (ACTIVE) signals
connecting the left side to this
output then this expression is
CLOSED (ACTIVE) for the
specified time.
This output should be used only
when the input signals are
DETECT OFF
ON or
DETECT ON
OFF. Only 8
Pulse outputs may be used.
3 ON Delay
Turn ON signal after specified
delay.
When there is a path of
CLOSED (ACTIVE) signals
connecting the left side to this
output, this expression will be
CLOSED (ACTIVE) after the
specified delay amount.
Only 4 ON DELAY outputs may
be used.
4 OFF Delay
Turn OFF signal after specified
delay.
When there is a path of
CLOSED (ACTIVE) sig
nals
connecting the left side to this
output, this expression will be
CLOSED
(ACTIVE) but when
the input path is OPEN
(INACTIVE) the signal wait for a
specified delay amount before
turning off.
Only 4 ON DELAY outputs may
be used.