11.3.3.11 Transferring and Updating Safety Logic Circuit File
After creating the safety logic circuit, press {READBACK}.
The safety logic circuit file is transferred to the safety circuit board.
When transferring of the safety logic circuit file is successfully
performed, the readback data from safety circuit board will show.
Button changes to {WRITE}.
Verify that there is no problem in readback data, then press {WRITE}.
the file transferred to the safety circuit board is written in the FLASH
ROM.
If {CANCEL} is pressed, the file will not update. Edited data is
discarded.
NOTE
When selecting {READBACK}, all output signals that are
outputted from the safety circuit board are turned OFF
until the writing process is completed.
When selecting {WRITE}, all information related to the
safety logic circuit is transferred to the safety circuit
board as the safety logic circuit file and written in the
FLASH ROM of the safety circuit board.
If the same output signal is used on multiple lines, an “!”
will be shown as following. While “!” is shown,
{READBACK} cannot proceed until the safety logic
circuit is corrected.