7 Concurrent I/O (Input/Output)
7.7 Block I/O
7-31
HW1485509
HW1485509
Block I/O Screen
To create a new Block I/O Configuration:
1. Go to {MENU} → {Program/Operate} → {Block I/O}.
– Block I/O screen will appear.
Fig. 7-25: Block I/O Setting
2. Select a state to edit, {OFF} or {ON}
– The selected state will be editable. The other state will appear
disabled but is still visible for the user to compare the contents of
both states. The list of commands can be edited in the same manner
as an INFORM program, described in chapter 7.3 “I/O Instructions”.
3. Press the {Test State} to execute the commands in the active state.
– A confirmation pop-up window will appear.
CAUTION
Testing Block I/O will execute I/O commands that may cause a
hazardous situation if not configured properly. Be careful before
executing Block I/O.