8. CreateamapattheNetVanta838thatinformstheunittoswitchdatafromagivenUser
toNetworkInterface(UNI),ataminimum,toaparticularEVC,andviceversa.
Formoreinformation,referto“CreateanEVCMap”onpage 424.
9. ProvisionpolicersintheNetVanta800.
10. Formore
information,referto“ProvisionPolicersintheNetVanta838”onpage 427.
11. ProvisionMACAddressLimitingandAging.
Forformoreinformation,referto“ProvisionMACAddressLimitingandAging”on
page 430.
12. Disableanyunusedinterfaces.
Formoreinformation,referto“DisableUnusedNetVanta838Interfaces”onpage 431.
Provision the 32-Port SHDSL EFM
Thissubsectiondetailsprovisioningthe32PortSHDSLEFMservicestate.
Provision the 32-Port SHDSL EFM Administration Status
The32PortSHDSLEFMcardservicestatemustbesettoInServiceorOutofService,Mainte
nance.
NOTE
Ifthecard servicestate is setto Outof Service,Maintenance, normal
operationoccursbutalarmsarenotreported.
Fortraffictopass,the32PortSHDSLEFMmodulemustbeenabled.
Table42displaysthethreeadministrationstatesandshowstheequivalentServiceStatefrom
priorreleases.
Tosetthemoduleadministrationandportadministrationstates,completethefollowing
procedure:
1. FromtheEnable
prompt,typeconfigure terminal,andpressENTERtoaccesstheGlo
balConfigurationprompt.
Table 4-2. 32-Port SHDSL EFM Administration States
Command Previous Description
no shutdown
InService
Inthe
no shutdownstate,trafficpasses
andalarmsaregenerated.
shutdown maintenance
OutofService,
Maintenance
Intheshutdown maintenancestate,traf
ficpassesbutnoalarmsaregenerated.
shutdown
OutofService,
Unassigned
Inthe shutdownstate,notrafficpasses
andnoalarmsaregenerated.

Table of Contents

Other manuals for ADTRAN Total Access 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADTRAN Total Access 5000 and is the answer not in the manual?

ADTRAN Total Access 5000 Specifications

Interfaces IconInterfaces
craft interfaceDB-9 RS-232 Electrical Interface (Async)
admin interfaceDB-9 RS-232 DTE Electrical Interface (Async with Modem Control Signals)
network management portDB-9 RS-232 DTE Electrical Interface (Async)
ethernet interface10Bt
external alarm inputs16
Operating Environment IconOperating Environment
operating temperature-40°C to +65°C
storage temperature-40°C to +70°C
relative humidityUp to 95%, non-condensing
Weight and Dimensions IconWeight and Dimensions
height9.25 in.
width0.08 in.
depth9.5 in.
weight0.6 lbs.