Total Access 5000 Business Services Deployment Guide
3-2 65K510DEP08-1A
Log On to the Total Access 5000
Forinitialdeployment,onlycraftaccessisavailable.AserialcablewithamaleDB9connector
ontheTotalAccess5000endisrequired.
TologontotheTotalAccess5000commandlineinterface,completethefollowing:
1. SettheparametersoftheVT100terminaltothefollowingsettings:
9600baud
rate
•8databits
•Noparity
•1stopbit
•Noflowcontrol
2. PlugthemaleendofthedatacableintotheTotalAccess5000.Makeaconnectiontothe
VT100terminaloraPCrunningemulationsoftwareasappropriatefortheequipment.
3. Aftercompletingtheprerequisiteproceduresabove,pressinganykeydisplays
thelogon
prompt.
TheTotalAccess5000SystemLogonpromptdisplaysthefollowinginformation:
User Access Verification
Username:
NOTE
Theaccountnameandpasswordarecasesensitive.
Defaultac countsareAD MIN,READONLY,READWRITE,andTEST.The
defaultpasswordforeachoftheseaccountsisPASSWORD.Theprivilegeto
change passwords, account names, andprivileges areincludedin the
ADMINaccount.Atthe
Usernamefield,inputtheUsername(ADMIN),and
pressENTER.
4. Atthe
Passwordfield,inputthePassword(PASSWORD),andpressENTER.
5. Uponenteringthecorrectpassword,theTotalAccess5000CLIintroductionbanner
displaysthefollowinginformation:
User Access Verification
Username:ADMIN
Password:********
Last Login Date : Nov 10 2008 10:19:17
Last Login Type : IP Session(CLI) - 192.168.1.3
Login Failures : 0 (Since Last Login)
: 14 (Total for Account)
TA5000>
6. Typeenable,andpressENTERtoenabletheprivilegedcommands.
TheTotalAccess5000systemdisplaysthefollowinginformation:
TA5000>enable
TA5000#

Table of Contents

Other manuals for ADTRAN Total Access 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADTRAN Total Access 5000 and is the answer not in the manual?

ADTRAN Total Access 5000 Specifications

Interfaces IconInterfaces
craft interfaceDB-9 RS-232 Electrical Interface (Async)
admin interfaceDB-9 RS-232 DTE Electrical Interface (Async with Modem Control Signals)
network management portDB-9 RS-232 DTE Electrical Interface (Async)
ethernet interface10Bt
external alarm inputs16
Operating Environment IconOperating Environment
operating temperature-40°C to +65°C
storage temperature-40°C to +70°C
relative humidityUp to 95%, non-condensing
Weight and Dimensions IconWeight and Dimensions
height9.25 in.
width0.08 in.
depth9.5 in.
weight0.6 lbs.