Section 4, EoCu Provisioning - Disable Unused NetVanta 838 Interfaces
65K510DEP08-1A 4-33
Disable Power Feed Alarms
Todisablethepowerfeedalarms,completethefollowingprocedure:
NOTE
Apowerfeedinputcannotbedisabled,butifbothinterfacesarenotbeing
sourcedwith±48VDCor ±24VDCpowering,thereisapowerfailalarm
activefortheunusedinput.
1. FromtheEnableprompt,type
configure terminal,andpressENTERtoaccesstheGlo
balConfigurationprompt.
2. FromtheGlobalConfigurationprompt,accessthesystemalarmpromptbytyping
system-alarm,andpressENTER.
3. IfpowerfeedAisunused,disablethepowerfeedAalarmbytyping
no alarm enable
power-fail dc a
,andpressENTER.
4. IfpowerfeedBisunused,disablethepowerfeedBalarmbytyping
no alarm enable
power-fail dc b
,andpressENTER.
5. Type
end,andpressENTERtoreturntotheEnableprompt.
ThepowerAorBfailalarmshouldbeclearedinthealarmlog.
Onceallunusedinterfacesaredisabled,thealarmsfortheseinterfacesshouldnowbecleared.
Ifallinuseinterfaces(SHDSL,Ethernet,GigabitEthernet,andpower)areinnonalarmed
states,
thentheAlarmLEDontheNetVanta838shouldnowbelitsolidgreen.
Clear the Alarm Log
BeforeclearingtheAlarmLog,thealarmsmustfirstbeacknowledged.
TocleartheAlarmLog,completethefollowingprocedure:
1. FromtheEnableprompt,type
force alarm acknowledge,andpressENTER.
2. Clearthealarmlogbytyping
force alarm clearandpressingENTER.
3. Verifytherearenoalarmsbytyping
show alarm logandpressingENTER.

Table of Contents

Other manuals for ADTRAN Total Access 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADTRAN Total Access 5000 and is the answer not in the manual?

ADTRAN Total Access 5000 Specifications

Interfaces IconInterfaces
craft interfaceDB-9 RS-232 Electrical Interface (Async)
admin interfaceDB-9 RS-232 DTE Electrical Interface (Async with Modem Control Signals)
network management portDB-9 RS-232 DTE Electrical Interface (Async)
ethernet interface10Bt
external alarm inputs16
Operating Environment IconOperating Environment
operating temperature-40°C to +65°C
storage temperature-40°C to +70°C
relative humidityUp to 95%, non-condensing
Weight and Dimensions IconWeight and Dimensions
height9.25 in.
width0.08 in.
depth9.5 in.
weight0.6 lbs.

Related product manuals