Appendix C, Ethernet OAM Provisioning - Ethernet OAM on the NetVanta 800/8000 Series NCTE
65K510DEP08-1A C-5
NetVanta 800/8000 Series NCTE Configuration Procedure
CreatetheMD,MA,andaMEPontheNetvanta800/8000SeriesNCTE#1(exampleatthe
end):
1. FromtheEnableprompt,type
configure terminal,andpressENTERtoaccesstheGlo
balConfigurationprompt.
2. FromtheGlobalConfigurationprompt,enabletheEthernetOAMsubsystembytyping
ethernet cfm,andpressENTER.
3. FromtheGlobalConfigurationprompt,createtheEthernetOAMMDbytyping
ethernet cfm domain char-string WORD level <0-7>,andpressENTER
UsethenameoftheMDinplaceoftheWORDfieldandspecifythelevelofMDafterthe
levelargument.
4. FromtheMDConfiguration,type
association char-string WORDtocreatetheMA
(oreditanexistingMA).
5. FromtheMAConfigurationprompt,type
ccm interval [1-minute|1-second|10-
minutes|10-seconds|100-milliseconds]
tosettheCCMinterval(defaultis1
second):
Use100milliseconds,1second,10seconds,1minute,or10minutesfortheCCM
interval.
6. TheNetVantasupportsremoteMEPautodiscoveryandautolearningwithinaMA.
AutodiscoveryletsalocalMEPdiscoveritspeerswithoutcommittingthemto
astate
wheretheycancauseRemoteCCMdefects/alarms.OtheralarmsforinvalidCCI,
MACstatus,orXconnectwillstillberaised.Discoverydoesnotcommitanyofthe
discoveredRMEPstoprovisioningandifaDiscoveredentryfails,itwillberemoved
fromthesystemafteragingout.Learningallowstheuser
toimmediatelylearnallpeers,
transitionthemtoStaticentries,andplacetheirvaluesinprovisioningsotheywillbe
persistenuponarestore.
TherearesevealitemsthatcomposetheMEPdatabaseandcontrolhowitoperates.
•MEPDatabase‐EachMAmanagesitsownMEPdatabase.TheMEPdatabase
contains
allRemoteMEPsandalsoconfigureshowRemoteMEPscanbeadded.
ConnectivityFailureInterval‐Thisvaluecannotbedirectlyconfiguredbyauserbut
isbasedoff oftheuserconfigurableCCMinterval.TheConnectivityFailureInterval
is3.5timestheCCMInterval.Itisoftenusedasthetimeframe
duringwhichcertain
eventsareexpectedtooccurwithin.OneexampleisifalocalMEPreceivesaCCM
fromaRMEPanddoesn’treceivesubsequentCCMfromitwithinthistimeframe,
thentheRMEP’sstateissetto‘Fail’.ForaMaintenanceAssociationusinga1second
CCMInterval,
ifalocalMEPreceivesaCCMfromaRMEPanddoesnotreceive
anotherwithin3.5seconds,theRMEPhasfailed.
•RemoteMEP‐RemoteMEPs(RMEP)aredefinedbytheirMEPIDwhichmustbe
uniqueacrosstheMA.ThevalidrangeforaMEPIDis18191.ARMEPcan
operate
inoneoftwomodes.Itcanbea‘Static’RMEPora‘Discovered’RMEP.The
operationmodeofaRMEPisdictatedbytheMEPdatabaseruleoftheMaintenance
Association.
–Static‐AStaticRMEPraisestheRemote CCMdefectconditionifittransitionsfrom
theOkstate
totheFailstate.AStaticRMEPwillalsobestoredinprovisioningafter
awriteandwillberestoredfollowingasubsequentreload.
–Discovered‐ADiscoveredRMEPdoesnotraisetheRemoteCCMdefectcondition
ifittransitionsfromtheOkstatetotheFailstate.AfterDiscoveredRMEPremains

Table of Contents

Other manuals for ADTRAN Total Access 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADTRAN Total Access 5000 and is the answer not in the manual?

ADTRAN Total Access 5000 Specifications

Interfaces IconInterfaces
craft interfaceDB-9 RS-232 Electrical Interface (Async)
admin interfaceDB-9 RS-232 DTE Electrical Interface (Async with Modem Control Signals)
network management portDB-9 RS-232 DTE Electrical Interface (Async)
ethernet interface10Bt
external alarm inputs16
Operating Environment IconOperating Environment
operating temperature-40°C to +65°C
storage temperature-40°C to +70°C
relative humidityUp to 95%, non-condensing
Weight and Dimensions IconWeight and Dimensions
height9.25 in.
width0.08 in.
depth9.5 in.
weight0.6 lbs.