Total Access 5000 Business Services Deployment Guide
C-4 65K510DEP08-1A
Ethernet OAM on the NetVanta 800/8000 Series NCTE
ToconfigureEthernetOAMontheNetVanta800/8000SeriesNCTE,completethefollowi ng
procedure:
1. EnableEthernetOAMontheNetVanta800/8000SeriesNCTE.
2. CreatetheEthernetOAMMD.
TheMDcontainsthefollowingattributes:
•Name
DomainLevel
3. WithinthenewlycreatedMD,createoneormoreEthernetOAMMaintenance
Associations(MA).
TheMAcontains
thefollowingattributes:
•Name
Component
Component’sPrimaryVID
CCMInterval
AssociatedRemoteMEPs
4. CreateMaintenanceEndPoints(MEP)andenableCCMs perMEP.
TheMEPcontainsthefollowingattributes:
•MEPID
•Direction
•Interface
•Priority
CCMTransmissionState
5. OnproductsthatsupportMIPs,edittheDefaultMD.
TheDefaultMDcontainsthefollowingattributes:
•DefaultMIPCreationRule
•DefaultMIPLevel
Component
Component’sPrimaryVID
Component’sMIPCreationRule
Component’sMIPLevel