Section 6, EoTDM Provisioning - Create an EVC Cross Connect
65K510DEP08-1A 6-15
Provisioning Steps
Thisprocessestablishesaconnectionbetweenthephysicalportandthevirtualnetwork.
TocreatetheEVC,completethefollowing :
1. FromtheEnableprompt,type
configure terminal,andpressENTERtogettotheGlo‐
balConfigurationprompt.
2. FromtheGlobalConfigurationprompt,type
evc <evc_name>,andpressENTER.
3. FromtheEVCI n terface Configurationprompt,type
s-tag <1-4094>,andpressENTER
tosettheS‐tagofthe EVC.
4. FromtheEVCI n terface Configurationprompt,type
connect men-port gigabit-
ethernet 1/A/1
,andpressENTERtoconnecttheactiveSMNet1interfacetotheEVC.
Thecon ne ctmen‐portgigabit‐ethernetcommandentryappliestotheactive
GigESM,independentofwhichGigE SMisactuallyspecified,inanAc tive/
Standbyconfiguration.
5. FromtheEVCI n terface Configurationprompt,type
connect men-port efm-group
<shelf/slot/group>
,andpressENTERtoconnecttheEFMbondinggrouptotheEVC.
TheEFMbondinggroupnamecanbeusedinlieuof the shelf/slot/group
designation.
6. FromtheEVCI n terface Configurationprompt,type
no shutdownandpressENTERto
enabletheEVC.
7. FromtheEVCI n terface Configurationprompt,type
endandpressENTERtoreturntothe
Enableprompt.
Table 6-4. Available S-tag Range
S-tag Function
0,1,4095 Reserved
2–4094 EVPLsandInbandManagementVLAN
3072 InternalManagementVLAN(Default)