EasyManua.ls Logo

ADTRAN Total Access 5000 - Provision the Line Module; Provision the CH DS3 PPP;MLPPP 3-Port Line Module Administration Status; Table 5-2. Line Module Administration States

ADTRAN Total Access 5000
352 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Total Access 5000 Business Services Deployment Guide
5-4 65K510DEP08-1A
Provision the Line Module
Thissectiondetailsprovisioningforthefollowingmodules:
•CHDS3PPP/MLPPP3PortLineModule
•DS1PPP/MLPPP32PortLineModule
Provision the CH DS3 PPP/MLPPP 3-Port Line Module
Administration Status
TheCHDS3PPP/MLPPP3PortLineModulecardservicestatemustbesettoInService,Out
ofService,orOutofServiceMaintenance.
NOTE
IfthecardservicestateissettoOutofServiceMaintenance,normal
operationoccursbutalarmsarenotreported.
LinecodeandlinebuildoutcannotbeprovisionedforeithertheDS3or
DS1.
Fortraffictopass,theCHDS3PPP/MLPPP3PortLineModulemustbeenabled.
Table52displaysthethreeadministrationstatesandshowstheequivalentServiceStatefrom
priorreleases.
Tosetthemoduleadministrationandportadministrationstates,completethefollowing
procedure:
1. FromtheEnableprompt,type
configure terminal,andpressENTERtoaccesstheGlo
balConfigurationprompt.
NOTE
Ifconnectedto the shelfwherethemoduleresides,theshelfnumberis
typically1.
Table 5-2. Line Module Administration States
Command Previous Description
no shutdown
InService
Inthe no shutdownstate,trafficpasses
andalarmsaregenerated.
shutdown maintenance
OutofService,
Maintenance
Intheno shutdownstate,trafficpasses
butnoalarmsaregenerated.Alarmsare
suppressedandnoevidenceofthealarm
isshown.
shutdown
OutofService,
Unassigned
Inthe
no shutdownstate,notraffic
passesandnoalarmsaregenerated.

Table of Contents