EasyManuals Logo

ADTRAN Total Access 5000 Deployment Guide

ADTRAN Total Access 5000
352 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #317 background imageLoading...
Page #317 background image
Appendix J, GigE Star Provisioning - Remote Terminal (RT) Provisioning
65K510DEP08-1A J-11
Provision the GE 4-Port Line Module
Thissubsectiondetailsthefollowing information:
•ProvisiontheGE4PortLineModuleServiceState
•ProvisiontheNetworkPorts
•ProvisiontheEthernetStar
•ProvisionforRedundancy
Provision the GE 4-Port Line Module Administration Status
TableJ2displaysthethreeadministrationstatesandshowstheequivalentServiceStatefrom
priorreleases.
Tosetthemoduleadministrationstate,completethefollowing:
1. FromtheTotalAccess5000Mainmenu,select
System CLI,andpressENTER.
2. FromtheCLImenu,select
CLI Command Entry,andpressENTER.
Thefollowingresponseiddisplayed:
Use EXIT to exit CLI session.
3. SelectYtoentertheCLIcommandinterface.
4. LoginagainusingthedefaultADM IN andPASSWORDoptions.TheCLIpromptis
displayed.
5. Type
enable,andpressENTERtoenabletheprivilegedcommands.
6. FromtheEnableprompt,type
configure terminal,andpressENTER.
7. FromtheGlobalConfigurationprompt,provisionthemoduleadministrationstateby
performingoneofthefollowingcommands:
•Type
no slot shutdown <shelf/slot>,andpressENTERtotakeaslotInService
•Typeslot
shutdown maintenance <shelf/slot>,andpressENTERtotakeaslot
OutofService,Maintenance
•Type
slot shutdown <shelf/slot>,andpressENTERtotakeaslotOutofService,
Unassigned
8. FromtheGlobalConfigurationprompt,type
interface gigabit-ethernet
<shelf/slot/port>
,andpressENTER.
Table J-5. GE 4-Port Line Module Administration States
Command Previous Description
no shutdown
InService
Inthe no shutdownstate,traffic
passesandalarmsaregenerated.
shutdown maintenance
OutofService,Main
tenance
Inthe
shutdown maintenance
state,trafficpassesbutnoalarmsare
generated.
shutdown
OutofService,Unas
signed
Inthe shutdownstate,notraffic
passesandnoalarmsaregenerated.

Table of Contents

Other manuals for ADTRAN Total Access 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADTRAN Total Access 5000 and is the answer not in the manual?

ADTRAN Total Access 5000 Specifications

Interfaces IconInterfaces
craft interfaceDB-9 RS-232 Electrical Interface (Async)
admin interfaceDB-9 RS-232 DTE Electrical Interface (Async with Modem Control Signals)
network management portDB-9 RS-232 DTE Electrical Interface (Async)
ethernet interface10Bt
external alarm inputs16
Operating Environment IconOperating Environment
operating temperature-40°C to +65°C
storage temperature-40°C to +70°C
relative humidityUp to 95%, non-condensing
Weight and Dimensions IconWeight and Dimensions
height9.25 in.
width0.08 in.
depth9.5 in.
weight0.6 lbs.

Related product manuals