EasyManua.ls Logo

ADTRAN Total Access 5000 - Provision the GE 4-Port Line Module; Provision the GE 4-Port Line Module Administration Status; Table J-5. GE 4-Port Line Module Administration States

ADTRAN Total Access 5000
352 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix J, GigE Star Provisioning - Remote Terminal (RT) Provisioning
65K510DEP08-1A J-11
Provision the GE 4-Port Line Module
Thissubsectiondetailsthefollowing information:
•ProvisiontheGE4PortLineModuleServiceState
•ProvisiontheNetworkPorts
•ProvisiontheEthernetStar
•ProvisionforRedundancy
Provision the GE 4-Port Line Module Administration Status
TableJ2displaysthethreeadministrationstatesandshowstheequivalentServiceStatefrom
priorreleases.
Tosetthemoduleadministrationstate,completethefollowing:
1. FromtheTotalAccess5000Mainmenu,select
System CLI,andpressENTER.
2. FromtheCLImenu,select
CLI Command Entry,andpressENTER.
Thefollowingresponseiddisplayed:
Use EXIT to exit CLI session.
3. SelectYtoentertheCLIcommandinterface.
4. LoginagainusingthedefaultADM IN andPASSWORDoptions.TheCLIpromptis
displayed.
5. Type
enable,andpressENTERtoenabletheprivilegedcommands.
6. FromtheEnableprompt,type
configure terminal,andpressENTER.
7. FromtheGlobalConfigurationprompt,provisionthemoduleadministrationstateby
performingoneofthefollowingcommands:
•Type
no slot shutdown <shelf/slot>,andpressENTERtotakeaslotInService
•Typeslot
shutdown maintenance <shelf/slot>,andpressENTERtotakeaslot
OutofService,Maintenance
•Type
slot shutdown <shelf/slot>,andpressENTERtotakeaslotOutofService,
Unassigned
8. FromtheGlobalConfigurationprompt,type
interface gigabit-ethernet
<shelf/slot/port>
,andpressENTER.
Table J-5. GE 4-Port Line Module Administration States
Command Previous Description
no shutdown
InService
Inthe no shutdownstate,traffic
passesandalarmsaregenerated.
shutdown maintenance
OutofService,Main
tenance
Inthe
shutdown maintenance
state,trafficpassesbutnoalarmsare
generated.
shutdown
OutofService,Unas
signed
Inthe shutdownstate,notraffic
passesandnoalarmsaregenerated.

Table of Contents