EasyManuals Logo

ADTRAN Total Access 5000 Deployment Guide

ADTRAN Total Access 5000
352 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #332 background imageLoading...
Page #332 background image
Total Access 5000 Business Services Deployment Guide
L-8 65K510DEP08-1A
Remote Terminal (RT) Provisioning
Todeploymultiplenodes,completethefollowing:
•ProvisiontheGigESM
Formoreinformation,referto“ProvisiontheGigESM”onpage L8.
•ProvisiontheRPRLineModule
Formoreinformation,referto“ProvisiontheRPRLineModule”onpage L9.
Provision the GigE SM
Thissubsectiondetailsthefollowing information:
•ProvisiontheTimingSource
•ProvisiontheHopCount
Provision the Timing Source
PrimaryandsecondarysourcesmustbeconfiguredtoreceivetimingfromLoopAandLoopB
whereLoopAisthelowernumbered(oddorWest)RPRLineModuleandLoopBisthehigher
numbered(evenorEast)RPRLineModule.Tosetthetiming,completethefollowing:
1. FromtheSwitchModulemenu,select
Provisioning,andpressENTER.
2. FromtheProvisioningmenu,select
Timing,andpressENTER.
3. FromtheTimingmenu,select
Primary Source,andpressENTER.
ThePrimarySourceprovisionsthelocalinputfortheprimaryclockgeneration.
4. FromthePrimaryTimingSourcemenu,select
Source,andpressENTER.
5. FromtheSourcemenu,select
LoopA,andpressENTER.
6. FromtheLoopAmenu,selecttheappropriateslot,andpress
ENTER.
7. FromtheTimingmenu,select
Secondary Source,andpressENTER.
TheSecondarySourceprovisionsthelocalinputforthesecondaryclockgeneration.
8. FromtheSecondaryTimingSourcemenu,select
Source,andpressENTER.
9. FromtheSourcemenu,select
LoopB,andpressENTER.
10. FromtheLoopBmenu,selecttheappropriateslot,andpress
ENTER.
Provision the Hop Count
HopCountmustbeenabled.ToenableHopCount,completethefollowing:
1. FromtheSwitchModulemenu,select
Provisioning,andpressENTER.
2. FromtheProvisioningmenu,select
Timing,andpressENTER.
3. FromtheTimingmenu,select
Hop Count,andpressENTER.
4. FromtheHopCountmenu,select
Enabled,andpressENTER.

Table of Contents

Other manuals for ADTRAN Total Access 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADTRAN Total Access 5000 and is the answer not in the manual?

ADTRAN Total Access 5000 Specifications

Interfaces IconInterfaces
craft interfaceDB-9 RS-232 Electrical Interface (Async)
admin interfaceDB-9 RS-232 DTE Electrical Interface (Async with Modem Control Signals)
network management portDB-9 RS-232 DTE Electrical Interface (Async)
ethernet interface10Bt
external alarm inputs16
Operating Environment IconOperating Environment
operating temperature-40°C to +65°C
storage temperature-40°C to +70°C
relative humidityUp to 95%, non-condensing
Weight and Dimensions IconWeight and Dimensions
height9.25 in.
width0.08 in.
depth9.5 in.
weight0.6 lbs.

Related product manuals