Section 3, Common Provisioning - Set the Date and Time
65K510DEP08-1A 3-3
NOTE
Theprivilegedcommands(Enableprompt)aredesignatedbythe#prompt.
Set the Date and Time
Tosetthedateandtime,completethefollowing:
1. FromtheEnableprompt,type
config term,andpressENTER.
2. FromtheGlobalConfigurationprompt,type
clock set <HH:MM:SS> <1-31> WORD
<2000-2036>
,andpressENTER.
3. Type
exit,andpressENTERtoreturntotheEnableprompt.
Provision the SNMP Interface
TheSNMPinterfaceisconfiguredtoprovidealmostallitemsaccessiblethroughtheTotal
Access5000CLI.Statusandperformancemonitoringparametersarereadonlyelements,
whereasconfigurationitemsarereadwrite.Theonlyitemsthatmaynotbechangedthrough
SNMParenetworkmanagementelementsthatwouldinterferewithproper
operationofthe
EthernetorInbandinterfaces,suchasIPaddresses,defaultroutes,etc.
NOTE
TheSNMPinformation isrequiredinorderfortheTotalAccessEMSto
interfacewiththeTotalAccess5000.
ToprovisiontheSNMPinformation,completethefollowing:
1. FromtheEnableprompt,type
config termandpressENTERtoaccesstheGlobalCon
figurationprompt.
2. FromtheGlobalConfigurationprompt,type
snmp-server host A.B.C.D,andpress
ENTERtoaddanSNMPserverentrytotheTotalAccess5000.
3. FromtheGlobalConfigurationprompt,type
snmp-server chassis-id WORDtoset
theSystemName,andpress
ENTER.
NOTE
The chassis nameis entered usingup to 55alphanumericcharacters
beginningwithalettercharacter withnospacesallowed.
4. FromtheGlobalConfigurationprompt,type
snmp-server location WORDtosetthe
SystemLocationtothedesiredlocationname,andpress
ENTER.
NOTE
TheSNMPserverlocationallowsspaces,specialcharacters,andupperand
lowercasecharacters.TheSNMPserverlocationislimitedto 55alpha
numericcharacters.

Table of Contents

Other manuals for ADTRAN Total Access 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADTRAN Total Access 5000 and is the answer not in the manual?

ADTRAN Total Access 5000 Specifications

Interfaces IconInterfaces
craft interfaceDB-9 RS-232 Electrical Interface (Async)
admin interfaceDB-9 RS-232 DTE Electrical Interface (Async with Modem Control Signals)
network management portDB-9 RS-232 DTE Electrical Interface (Async)
ethernet interface10Bt
external alarm inputs16
Operating Environment IconOperating Environment
operating temperature-40°C to +65°C
storage temperature-40°C to +70°C
relative humidityUp to 95%, non-condensing
Weight and Dimensions IconWeight and Dimensions
height9.25 in.
width0.08 in.
depth9.5 in.
weight0.6 lbs.