Section 7, EoF Provisioning - Create an EVC Map
65K510DEP08-1A 7-13
Provisioning Steps
Tocreatethemap,completethefollowingprocedure:
1. FromtheEnableprompt,type
configure terminal,andpressENTERtoaccesstheGlo
balConfigurationprompt.
2. FromtheGlobalConfigurationprompt,type
evc-map WORD,andpressENTERtocreate
themapandenterthemapconfigurationmode.
Thisattributeisanarbitrarystringthatisusedtoidentifythemap.Thevaluemustbe
uniqueacrossallmapsdefinedintheproductandisintendedformanagementand
controlpurposes.Thevalueisnotcarriedinanyfield
intheEthernet frame.
Configure the Map
TheUsertoNetworkInterface(UNI)andtheEVCmustbeconfiguredforthemap.Amap
bindstheUNItraffictotheEVC.Toconfigurethemap,completethefollowingprocedure:
1. FromtheEVCMapInterfaceConfigurationprompt,settheUNIbytyping
connectuni
gigabit-ethernet
followedbytheethernetportnumberin1/0/portformat,and
press
ENTER.
NOTE
FortheNetVanta,theshelfisalways1andtheslotisalwayszero.
2. FromtheEVCMapConfigurationprompt,connectthenewmaptotheEVCbytyping
connect evc WORD,andpressENTER.
ThisattributeisthenameoftheEVCassociatedwiththemapandmustbespecified.
3. FromtheEVCMapConfigurationprompt,enablethemapbytyping
no shutdown,and
press
ENTER.
4. FromtheEVCMapConfigurationprompt,type
end,andpressENTERtoreturntothe
Enableprompt.
5. Tosavethechangestononvolatilememory,type
copy running-config startup-
config
,andpressENTER.
6. FromtheEnableprompt,viewthenewmapbytypingshow evc-map WORD,andpress
ENTER.
ThiscommandalsodisplaystheEVCandUNIthatthemapisattachedto.
Oncethisprocessiscompleted,datacanberunthroughthesystem.
Map Example
Thefollowingisasampleoutputoftheshowinterfacesmapcommandformap1200.
MyNV8044show evc-map map100
EVC-map map100
Admin State : Enabled
EVC-map Status : Running
Connected EVC : evc1100 (1200)

Table of Contents

Other manuals for ADTRAN Total Access 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADTRAN Total Access 5000 and is the answer not in the manual?

ADTRAN Total Access 5000 Specifications

Interfaces IconInterfaces
craft interfaceDB-9 RS-232 Electrical Interface (Async)
admin interfaceDB-9 RS-232 DTE Electrical Interface (Async with Modem Control Signals)
network management portDB-9 RS-232 DTE Electrical Interface (Async)
ethernet interface10Bt
external alarm inputs16
Operating Environment IconOperating Environment
operating temperature-40°C to +65°C
storage temperature-40°C to +70°C
relative humidityUp to 95%, non-condensing
Weight and Dimensions IconWeight and Dimensions
height9.25 in.
width0.08 in.
depth9.5 in.
weight0.6 lbs.