Provision MAC Address Limiting and Aging
TopreventMACAddressstormsatthecustomerEthernet/GigabitEthernetports,the
NetVanta800seriessupportsMACAddressLimiting.TheNetVantalearnsMACaddresses
fromtrafficingressingthecustomerinterface;oncetheNetVantalearnstheprovisionedlimit,
itdoesnotallowanyadditionalMACaddressestopasstowardthenetwork.MAC
Address
Limitingcanalsobedisabled.Bydefault,NetVantahasMACAddressLimitingdisabled.
Ifenabled,MACAddressagingcanbeused.Bydefault,theMACAgingtimeoutis5
minutes.TheMACAgingTimeoutcanbesettoanyvaluefrom1to3600seconds.Ifsetto
zero,MAC
Agingisdisabled,andlearnedMACaddressesarelocked.
TosettheMACAddressLimitcountandagingvalues,completethefollowi ngsteps:
1. FromtheEnableprompt,type
configure terminal,andpressENTERtoaccesstheGlo
balConfigurationprompt.
2. FromtheGlobalConfigurationprompt,accesstheGigabitEthernetConfiguration
promptbytyping
interface gigabit-ethernet 1/0/1,andpressENTERtoaccessthe
GigabitEthernetConfigurationprompt.
3. Type
mac limit <# of MAC addresses>,andpressENTERtosetthemaximumnumber
ofMACAddressesallowedontheselectedinterface,from1to100addresses.
NOTE
TodisableMAClimiting,typeno mac limit,andpressENTER.
4. Type
mac aging-time <timeout_value>,andpressENTERtosettheMACAddress
AgingTimeoutvaluefortheselectedinterface,wheretimeout_valueisthenewtimeout
valueinseconds,between0(MACagingisdisabled)and3600seconds.
5. Type
end,andpressENTERtoreturntotheEnableprompt.

Table of Contents

Other manuals for ADTRAN Total Access 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADTRAN Total Access 5000 and is the answer not in the manual?

ADTRAN Total Access 5000 Specifications

Interfaces IconInterfaces
craft interfaceDB-9 RS-232 Electrical Interface (Async)
admin interfaceDB-9 RS-232 DTE Electrical Interface (Async with Modem Control Signals)
network management portDB-9 RS-232 DTE Electrical Interface (Async)
ethernet interface10Bt
external alarm inputs16
Operating Environment IconOperating Environment
operating temperature-40°C to +65°C
storage temperature-40°C to +70°C
relative humidityUp to 95%, non-condensing
Weight and Dimensions IconWeight and Dimensions
height9.25 in.
width0.08 in.
depth9.5 in.
weight0.6 lbs.

Related product manuals