Section 2, Installation - Install the Front Panel Modules
65K510DEP08-1A 2-25
Apply Power and Verify the Self-Test Passes
TheTotalAccess5000SMIO3deliverstwo–48VDCbusestotheSCM.TheSCMoperates
withbothoreither–48VDCbusesactive.
Allpower,ground,andadministrativewiringshouldnowbecompletedontheTotalAccess
5000shelf,andanSCMshouldbeinstalledinslot
12/SCMoftheshelf.Toapp ly power,
completethefollowingprocedure:
1. Insertafuseintothefuseandalarmpanel.Thefuseshouldbeselectedwithanamperage
appropriatefortheintendeduseoftheTotalAccess5000shelf.
2. Verifythatthe poweronselftestroutinehascompletedsuccessfullyforeach
component.
Whenpowerisapplied,eachcomponentperformsaseriesofinitializationselftests.
Oncecompleted,thefrontpanelLEDsreflectthetruestateofthehardware.Referto
Table23toverifytheselftestLEDindications.
Table 2-3. LED Self-test Indications
Label Status Description
SCM
PWR
{
z
z
Off
Green
Red
Nopowertounit
PowerandinitializationOK
Power,temp,orbootfailure
GigESM
PWR
{
z
z
Off
Green
Red
Nopowertounit
PowerandinitializationOK
Power,temp,orbootfailure
SHDSLEFM
PWR
{
z
z
z
Off
Green
Yellow
Red
Nopowertounit
PowerandinitializationOK
Powerandoutofservice
Power,temp,orbootfailure
EFMBondingProtectionModule
PWR
{
z
z
z
Off
Green
Yellow
Red
Nopowertounit
PowerandinitializationOK
Powerandoutofservice
Power,temp,orbootfailure
CHDS3PPP/MLPPP3Port
PWR
{
z
z
z
Off
Green
Yellow
Red
Nopowertounit
PowerandinitializationOK
Powerandoutofservice
Power,temp,orbootfailure