Provision for Redundancy
Toprovisionforredundancy,completethefollowing:
NOTE
TomaketheGE4Po r t LineModuleinthe od dslottheactivemodule,
provisionitfirst.
1. FromtheEnableprompt,type
configure terminal,andpressENTER toaccesstheGlo
balConfigurationprompt.
2. FromtheGlobalConfigurationprompt,type
redundancy <shelf/slot>.andpress
ENTER.
3. FromtheRedundancyConfigurationprompt,type
no shutdown,andpressENTER.
NOTE
RedundancyisnotfullyenableduntiltheevenslotisalsoInService.
4. Repeatsteps2and3fortheGE4PortLineModuleintheevenslot.
Provision the DS3 Unchannelized EFM 4-Port Line Module
Thissubsectiondetailsthefollowing information:
•ProvisiontheDS3UnchannelizedEFM4PortLineModule
•ProvisiontheUplinkIdentifer
•ProvisiontheTimingSource
Provision the DS3 Unchannelized EFM 4-Port Line Module
Administration Status
TableJ3displaysthethreeadministrationstatesandshowstheequivalentServiceStatefrom
priorreleases.
Tosetthemoduleadministrationstate,completethefollowing:
Table J-3. DS3 Unchannelized EFM 4-Port Module Administration States
Command Previous Description
no shutdown
InService
Inthe no shutdownstate,traffic
passesandalarmsaregenerated.
shutdown maintenance
OutofService,Main
tenance
Inthe
shutdown maintenance
state,trafficpassesbutnoalarmsare
generated.
shutdown
OutofService,Unas
signed
Inthe
shutdownstate,notraffic
passesandnoalarmsaregenerated.