Total Access 5000 Business Services Deployment Guide
H-2 65K510DEP08-1A
Introduction
TotalAccessSystemRelease4.5allowstheusertoconfigurethealarmseveritylevelforallT3
andT1faultalarms,along withbeingabletoenableordisableallalarms.Thealarmseverities
areprovisionedonaper‐slotbasis.
Default Severities
TableH‐2displaystheT3andT1alarmsandtheirdefaultseverities.
T3 Alarm Severity Level
TosetthealarmseveritylevelforaT3alarm,completethefollowingsteps:
1. FromtheEnableprompt,type
configure terminal,andpressENTERtoaccesstheGlo‐
balConfigurationprompt.
2. FromtheGlobalConfigurationprompt,type
interface t3 <shelf/slot/port>,and
press
ENTERtoaccesstheT3Configurationprompt.
3. FromtheT3Configurationprompt,type
alarm level <alarm_name>
<alarm_level>
,andpressENTERtosetthealarmseveritylevel.RefertoTableE‐2for
validalarm_na meandalarm_levelvalues.
4. FromtheT3Configurationprompt,provisionthealarmstatusbyperformingoneofthe
followingcommands:
•Type
no alarm enable <alarm_name>,andpressENTERtodisablethespecified
alarm
•Type
alarm enable <alarm_name>,andpressENTERtoenablethespecifiedalarm
5. FromtheT3Configurationprompt,type
end,andpressENTERtoreturntotheEnable
prompt.
TableH‐3displaystheT3ParameterValues.
Table H-2. Default Severities
Alarm Default
T3AlarmDefaults
LOS Major
LOF Major
RAI Minor
AIS Major
T1AlarmDefaults
LOF Major
RAI Minor
AIS Major