ADTRAN Total Access 5000 - Default Severities; T3 Alarm Severity Level; Table H-2. Default Severities

ADTRAN Total Access 5000
352 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Total Access 5000 Business Services Deployment Guide
H-2 65K510DEP08-1A
Introduction
TotalAccessSystemRelease4.5allowstheusertoconfigurethealarmseveritylevelforallT3
andT1faultalarms,along withbeingabletoenableordisableallalarms.Thealarmseverities
areprovisionedonaperslotbasis.
Default Severities
TableH2displaystheT3andT1alarmsandtheirdefaultseverities.
T3 Alarm Severity Level
TosetthealarmseveritylevelforaT3alarm,completethefollowingsteps:
1. FromtheEnableprompt,type
configure terminal,andpressENTERtoaccesstheGlo
balConfigurationprompt.
2. FromtheGlobalConfigurationprompt,type
interface t3 <shelf/slot/port>,and
press
ENTERtoaccesstheT3Configurationprompt.
3. FromtheT3Configurationprompt,type
alarm level <alarm_name>
<alarm_level>
,andpressENTERtosetthealarmseveritylevel.RefertoTableE2for
validalarm_na meandalarm_levelvalues.
4. FromtheT3Configurationprompt,provisionthealarmstatusbyperformingoneofthe
followingcommands:
•Type
no alarm enable <alarm_name>,andpressENTERtodisablethespecified
alarm
•Type
alarm enable <alarm_name>,andpressENTERtoenablethespecifiedalarm
5. FromtheT3Configurationprompt,type
end,andpressENTERtoreturntotheEnable
prompt.
TableH3displaystheT3ParameterValues.
Table H-2. Default Severities
Alarm Default
T3AlarmDefaults
LOS Major
LOF Major
RAI Minor
AIS Major
T1AlarmDefaults
LOF Major
RAI Minor
AIS Major

Table of Contents