Appendix J, GigE Star Provisioning - Central Office Terminal (COT) Provisioning
65K510DEP08-1A J-3
5. Typeenable,andpressENTERtoenabletheprivilegedcommands.
6. FromtheEnableprompt,type
configure terminal,andpressENTER.
7. FromtheGlobalConfigurationprompt,provisionthemoduleadministrationstateby
performingoneofthefollowingcommands:
•Type
no slot shutdown <shelf/slot>,andpressENTERtotakeaslotInService
•Typeslot
shutdown maintenance <shelf/slot>,andpressENTERtotakeaslot
OutofService,Maintenance
•Type
slot shutdown <shelf/slot>,andpressENTERtotakeaslotOutofService,
Unassigned
8. FromtheGlobalConfigurationprompt,type
interface gigabit-ethernet
<shelf/slot/port>
,andpressENTER.
9. Provisiontheportadministrationstatebyperformingoneofthefollowingcommands:
•Type
no shutdown,andpressENTERtotakeaportInService
•Type
shutdown maintenance,andpressENTERtotakeaportOutofService,Mainte
nance
•Type
shutdown,andpressENTERtotakeaportOutofService,Unassigned
Provision the Network Ports
Toconfigurethenetworkportadministrationstates,completethefollowing:
1. FromtheEnableprompt,type
configure terminal,andpressENTERtoaccesstheGlo
balConfigurationprompt.
2. FromtheGlobalConfigurationprompt,type
interface gigabit-ethernet
<shelf/slot/port>
,andpressENTERtoaccesstheEthernetInterfaceConfiguration
prompt.
3. Type
no shutdown,andpressENTERtosettheporttoInService.
4. Repeatsteps2and3foreachportbeingused.
Provision the Ethernet Star
ToconfiguretheTotalAccess5000foraGigabitEthernetStar,completethefollowing:
1. FromtheEnableprompt,type
configure terminal,andpressENTERtoaccesstheGlo
balConfigurationprompt.
2. FromtheGlobalConfigurationprompt,type
interface gigabit-ethernet
<shelf/slot/port>
,andpressENTERtoaccesstheEthernetInterfaceConfiguration
prompt.
3. FromtheEthernetInterfaceConfigurationprompt,type
downlink,andpressENTER.
Thedownlinkcommandenablesdownstreamtreenetworkingontheselectedinterface.

Table of Contents

Other manuals for ADTRAN Total Access 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADTRAN Total Access 5000 and is the answer not in the manual?

ADTRAN Total Access 5000 Specifications

Interfaces IconInterfaces
craft interfaceDB-9 RS-232 Electrical Interface (Async)
admin interfaceDB-9 RS-232 DTE Electrical Interface (Async with Modem Control Signals)
network management portDB-9 RS-232 DTE Electrical Interface (Async)
ethernet interface10Bt
external alarm inputs16
Operating Environment IconOperating Environment
operating temperature-40°C to +65°C
storage temperature-40°C to +70°C
relative humidityUp to 95%, non-condensing
Weight and Dimensions IconWeight and Dimensions
height9.25 in.
width0.08 in.
depth9.5 in.
weight0.6 lbs.