EasyManua.ls Logo

ADTRAN Total Access 5000 - T1 Alarm Severity Level; Table H-3. T3 Parameter Values; Table H-4. T1 Parameter Values

ADTRAN Total Access 5000
352 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix H, Alarm Severities - T1 Alarm Severity Level
65K510DEP08-1A H-3
T1 Alarm Severity Level
TosetthealarmseveritylevelforaT3alarm,completethefollowingsteps:
1. FromtheEnableprompt,type
configure terminal,andpressENTERtoaccesstheGlo
balConfigurationprompt.
2. FromtheGlobalConfigurationprompt,type
interface t1 <shelf/slot/
port:channel>
,andpressENTERtoaccesstheT1Configurationprompt.
3. FromtheT1Configurationprompt,type
alarm level <alarm_name>
<alarm_level>
,andpressENTERtosetthealarmseveritylevel.RefertoTableH4for
validalarm_na meandalarm_levelvalues.
TableH4displaystheT3ParameterValues.
4. FromtheT1Configurationprompt,provisionthealarmstatusbyperformingoneofthe
followingcommands:
•Type
no alarm enable <alarm_name>,andpressENTERtodisablethespecified
alarm
•Type
alarm enable <alarm_name>,andpressENTERtoenablethespecifiedalarm
5. FromtheT1Configurationprompt,type
end,andpressENTERtoreturntotheEnable
prompt.
Table H-3. T3 Parameter Values
alarm_name alarm_level
LOS Critical
LOF Major
RAI Minor
AIS Alert
Information
Table H-4. T1 Parameter Values
alarm_name alarm_level
LOF Critical
RAI Major
AIS Minor
Alert
Information