Section 7, EoF Provisioning - Configure Subtended Host Information
65K510DEP08-1A 7-5
Configure Subtended Host Information
Toconfigurethesubtendedhost information,completethefollowing:
1. FromtheEnableprompt,type
configure terminal,andpressENTERtogettotheGlo
balConfigurationprompt.
2. FromtheGlobalConfigurationprompt,type
interface gigabit-ethernet
<shelf/slot/port>
,andpress ENTER.
3. FromtheGigabitEthernetInterfaceConfigurationprompt,type
subtended-host ip
address A.B.C.D E.F.G.H
,andpressENTER.
4. FromtheGigabitEthernetInterfaceConfigurationprompt,type
subtended-host ip
default-gateway A.B.C.D
,andpressENTER.
5. FromtheGigabitEthernetInterfaceConfigurationprompt,type
subtended-host ip
file-server default host A.B.C.D
,andpressENTER.
6. FromtheGigabitEthernetInterfaceConfigurationprompt,type
subtended-host
mode
,andpressENTER.
7. FromtheGigabitEthernetInterfaceConfigurationprompt,type
subtended-host s-
tag <1-4094>
,andpressENTER.
8. FromtheGigabitEthernetInterfaceConfigurationprompt,type
subtended-host
s-tag-priority
,andpressENTER.
9. FromtheGigabitEthernetInterfaceConfigurationprompt,type
subtended-host
snmp-server chassis-id
,andpressENTER.
10. FromtheGigabitEthernetInterfaceConfigurationprompt,type
subtended-host
snmp-server community read-only
,andpressENTER.
11. FromtheGigabitEthernetInterfaceConfigurationprompt,type
subtended-host
snmp-server community read-write
,andpressENTER.