EasyManuals Logo

ADTRAN Total Access 5000 Deployment Guide

ADTRAN Total Access 5000
352 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #191 background imageLoading...
Page #191 background image
Section 7, EoF Provisioning - Configure Subtended Host Information
65K510DEP08-1A 7-5
Configure Subtended Host Information
Toconfigurethesubtendedhost information,completethefollowing:
1. FromtheEnableprompt,type
configure terminal,andpressENTERtogettotheGlo
balConfigurationprompt.
2. FromtheGlobalConfigurationprompt,type
interface gigabit-ethernet
<shelf/slot/port>
,andpress ENTER.
3. FromtheGigabitEthernetInterfaceConfigurationprompt,type
subtended-host ip
address A.B.C.D E.F.G.H
,andpressENTER.
4. FromtheGigabitEthernetInterfaceConfigurationprompt,type
subtended-host ip
default-gateway A.B.C.D
,andpressENTER.
5. FromtheGigabitEthernetInterfaceConfigurationprompt,type
subtended-host ip
file-server default host A.B.C.D
,andpressENTER.
6. FromtheGigabitEthernetInterfaceConfigurationprompt,type
subtended-host
mode
,andpressENTER.
7. FromtheGigabitEthernetInterfaceConfigurationprompt,type
subtended-host s-
tag <1-4094>
,andpressENTER.
8. FromtheGigabitEthernetInterfaceConfigurationprompt,type
subtended-host
s-tag-priority
,andpressENTER.
9. FromtheGigabitEthernetInterfaceConfigurationprompt,type
subtended-host
snmp-server chassis-id
,andpressENTER.
10. FromtheGigabitEthernetInterfaceConfigurationprompt,type
subtended-host
snmp-server community read-only
,andpressENTER.
11. FromtheGigabitEthernetInterfaceConfigurationprompt,type
subtended-host
snmp-server community read-write
,andpressENTER.

Table of Contents

Other manuals for ADTRAN Total Access 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADTRAN Total Access 5000 and is the answer not in the manual?

ADTRAN Total Access 5000 Specifications

Interfaces IconInterfaces
craft interfaceDB-9 RS-232 Electrical Interface (Async)
admin interfaceDB-9 RS-232 DTE Electrical Interface (Async with Modem Control Signals)
network management portDB-9 RS-232 DTE Electrical Interface (Async)
ethernet interface10Bt
external alarm inputs16
Operating Environment IconOperating Environment
operating temperature-40°C to +65°C
storage temperature-40°C to +70°C
relative humidityUp to 95%, non-condensing
Weight and Dimensions IconWeight and Dimensions
height9.25 in.
width0.08 in.
depth9.5 in.
weight0.6 lbs.

Related product manuals