EasyManuals Logo

ADTRAN Total Access 5000 Deployment Guide

ADTRAN Total Access 5000
352 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #244 background imageLoading...
Page #244 background image
Total Access 5000 Business Services Deployment Guide
F-4 65K510DEP08-1A
EVCs
TheMEFdefinesanEVCas“anassociationoftwoormoreUNIs,”whereaUNIisastandard
10/100/1000EthernetinterfacethatisthepointofdemarcationbetweentheCEandtheMEN
oftheserviceprovider.Insimpleterms,anEVCperformstwofunctions.
Connectstwoormoresubscriber
sites(UNIs)enablingthetransferofEthernetservice
frames
•PreventsdatatransferbetweensubscribersitesthatarenotpartofthesameEVC
ThiscapabilityenablesanEVCtoprovidedataprivacyandsecuritysimilartoaFrame
RelayorATMPermanentVirtualCircuit(PVC).
MultipleEVCscanresideonacommon
bondinggrouporEthernetport.EachEVChasan
associatedEVCwhoseVLANIDisunique amongotherEVCsintheMEN.TheEVCstag
allowstheEVCtobeidentifiedandseparatedfromotherEVCswithintheMEN.TheEVCs
tagexistsonlywithintheMENandis
nottransmittedfromorreceivedattheCE.
TheMEFdefinesEthernetLine(ELine)servicesasaservicethatprovidesapointtopoint
EVCthatconnectsexactlytwoUNIs.
EVC Attributes
TheattributesofanEVCaredescribedinthefollowingparagraphs.
Name
ThisattributeisanarbitrarystringthatisusedtoidentifytheEVCwithintheMEN.Thevalue
mustbeuniqueacrossallEVCsdefinedinthenetworkelement,andisintendedfor
managementandcontrolpurposes.ThevalueisnotcarriedinanyfieldintheEthernetframe.
Asan
example,theAcmeServiceProvidercanuse“EVC0001898ACMEMEGAMA RT”to
representthe1898thEVCintheMEN.Inthisexample,thecustomerfortheEVCisMegaMart.
Configuration Status
Thisreadonlyattributeind icatesthecurrentstatusoftheEV C.TheEVCcanbeadministra
tivelyenabled,butcannotbeinthefunctionalstateifitisnotfullyconfiguredorifaconflict
exists.IftheEVCisnotappliedduetotheconfig urationoraconflict,refer
toTableF 3fora
listsofthepossiblevalues.
Table F-3. EVC Status Values
Possible Values Definition
Running ConditionsareokayandtheEVCprovisioningisapplied.
MissingConnection TheEVCisnotconnectedtoenoughactiveinterfaces.Themini
mumrequiredistwo.Theactiveinterfacecanbedirectlycon
nectedbyMENportormappedUNI.
TagConflict AnotherEVCisadministrativelyenabledandconfiguredtouse
thesame
stag.
Disabled TheStatevalueoftheEVCisprovisionedasdisabled.
SystemmanagementevcCon
flict
TheEVCstagisinusebythesystemmanagementEVC.

Table of Contents

Other manuals for ADTRAN Total Access 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADTRAN Total Access 5000 and is the answer not in the manual?

ADTRAN Total Access 5000 Specifications

Interfaces IconInterfaces
craft interfaceDB-9 RS-232 Electrical Interface (Async)
admin interfaceDB-9 RS-232 DTE Electrical Interface (Async with Modem Control Signals)
network management portDB-9 RS-232 DTE Electrical Interface (Async)
ethernet interface10Bt
external alarm inputs16
Operating Environment IconOperating Environment
operating temperature-40°C to +65°C
storage temperature-40°C to +70°C
relative humidityUp to 95%, non-condensing
Weight and Dimensions IconWeight and Dimensions
height9.25 in.
width0.08 in.
depth9.5 in.
weight0.6 lbs.

Related product manuals