Section 7, EoF Provisioning - Provisioning Summary
65K510DEP08-1A 7-3
Provisioning Summary
TocreateadatapathfromtheGigESMportontheTotalAccess5000toanEthernetporton
theNetVanta8044,completethefol lowing procedure:
1. ProvisiontheGE8 PortLineModule.
Formoreinformation,referto“ProvisiontheGE8PortLineModule”onpage 74.
2. Configurethe
subtendedhostinformation.
Formoreinformation,referto“ConfigureSubtendedHostInformation”onpage 75.
3. CreateanEthernetVirtualCircuit(EVC)attheTotalAccess5000thatconnectsthe
GigabitEthernetportofthedefaultethernetinterface.
ThiscreatesthemappingoftheStaggeddata.Thisaccomplishesthefollowing:
•TheGigE
SMknowswheretosendthetaggedtrafficcominginfromthedefault
ethernetinterface
•TheGigESMpushestheavailabletagstoeachGE8PortLMandtoeachNetVanta
8044forthelocalNetVanta8044provisioning
Formoreinformation,referto“CreateanEVCCrossConnect”onpage 76.
4. LogontotheNetVanta8044.
Formoreinformation,referto“LogOntotheNetVanta8044onpage 78.
5. CreatetheEVCattheNetVanta8044.
TheEVCisaconnectionbetweentwophysicalports.
Formoreinformation,referto“CreateanEVC”onpage 79.
6. CreateamapattheNetVanta
8044thatinformstheunittoswitchdatafromagiv enUser
toNetworkInterface(UNI),ataminimum,toaparticularEVC,andviceversa.
Formoreinformation,referto“CreateanEVCMap”onpage 712.
7. ProvisionpolicersintheNetVanta8044.
Formoreinformation,referto“ProvisionPolicers
intheNetVanta8044”onpage 714.
8. ProvisionMACAddressLimitingandAging.
Forformoreinformation,referto“ProvisionMACAddressLimitingandAging”on
page 717.
9. Disableanyunusedinterfaces.
Formoreinformation,referto“DisableUnusedNetVanta8044Interfaces”onpage 718.

Table of Contents

Other manuals for ADTRAN Total Access 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADTRAN Total Access 5000 and is the answer not in the manual?

ADTRAN Total Access 5000 Specifications

Interfaces IconInterfaces
craft interfaceDB-9 RS-232 Electrical Interface (Async)
admin interfaceDB-9 RS-232 DTE Electrical Interface (Async with Modem Control Signals)
network management portDB-9 RS-232 DTE Electrical Interface (Async)
ethernet interface10Bt
external alarm inputs16
Operating Environment IconOperating Environment
operating temperature-40°C to +65°C
storage temperature-40°C to +70°C
relative humidityUp to 95%, non-condensing
Weight and Dimensions IconWeight and Dimensions
height9.25 in.
width0.08 in.
depth9.5 in.
weight0.6 lbs.