Total Access 5000 Business Services Deployment Guide
3-6 65K510DEP08-1A
Provision the GigE SM
Thissectiondetailsthefollowinginformation:
•ProvisiontheGigESMadministrationstate
•Provisionthenetworkports
•Provisionthenetworkportmodes
•ProvisiontheLACPswitchovermode
•ProvisionforLinkAggregationControlProtocol(LACP)
•Provisionthetimingsource
Provision the GigE SM Administration Status
Fortraffictopass,theGigESMmodulemustbeenabled.
Table32displaysthethreeadministrationstatesandtheequivalentservicestatesfromprior
releases.
Tosetthemoduleadministrationstate,completethefollowingprocedure:
1. FromtheEnableprompt,type
configure terminal,andpressENTERtoaccesstheGlo
balConfigurationprompt.
2. FromtheGlobalConfigurationprompt,provisionthemoduleadministrationstateby
enteringoneofthefollowingcommands:
•Type
no slot shutdown <shelf/slot>,andpressENTERtotakeacardInService
NOTE
Ifconnectedtotheshelfwherethemoduleresides,theshelfnumberis
typically1.
Thisistheslotofthemodulebeingconfigured.ValidvaluesfortheSwitch
ModulesareAandB.
•Type
slot shutdown maintenance <shelf/slot>,andpressENTERtotakea
cardOutofService,Maintenance
•Type
slot shutdown <shelf/slot>,andpressENTERtotakeacardOutofService,
Unassigned
Table 3-2. GigE SM Administration States
Command Previous Description
no shutdown
InService
Inthe no shutdownstate,trafficpasses
andalarmsaregenerated.
shutdown maintenance
OutofService,
Maintenance
Inthe
shutdown maintenancestate,
trafficpassesbutnoalarmsaregenerated.
Alarmsaresuppressedandnoevidenceof
thealarmisshown.
shutdown
OutofService,
Unassigned
Inthe
shutdownstate,notrafficpasses
andnoalarmsaregenerated.

Table of Contents

Other manuals for ADTRAN Total Access 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADTRAN Total Access 5000 and is the answer not in the manual?

ADTRAN Total Access 5000 Specifications

Interfaces IconInterfaces
craft interfaceDB-9 RS-232 Electrical Interface (Async)
admin interfaceDB-9 RS-232 DTE Electrical Interface (Async with Modem Control Signals)
network management portDB-9 RS-232 DTE Electrical Interface (Async)
ethernet interface10Bt
external alarm inputs16
Operating Environment IconOperating Environment
operating temperature-40°C to +65°C
storage temperature-40°C to +70°C
relative humidityUp to 95%, non-condensing
Weight and Dimensions IconWeight and Dimensions
height9.25 in.
width0.08 in.
depth9.5 in.
weight0.6 lbs.

Related product manuals