EasyManuals Logo

ADTRAN Total Access 5000 Deployment Guide

ADTRAN Total Access 5000
352 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #211 background imageLoading...
Page #211 background image
Appendix A, Link Aggregation Guide - Remove Link Aggregation Provisioning
65K510DEP08-1A A-7
ToredirecttheEVCstoaGigabitEthernetport,completethefollowingprocedure:
1. Fromtherootprompt,type
show evc,andpressENTERtodisplayallEVCsintheTotal
Access5000.
ForanyEVCsthatareconnectedtotheGigabitEthernetport,performthefollowing
stepstodisconnectthemfromtheGEportandconnectthemtotheLAGgroup.
2. FromtheEnableprompt,type
configure terminal,andpressENTERtoaccessthe
GlobalConfigurationprompt.
3. FromtheGlobalConfigurationprompt,type
evc <shelf/slot/index>, andpress
ENTERtoaccesstheEVCInterfaceConfigurationprompt.
4. FromtheEVCI n terface Configurationprompt,type
no connect men-port lag-
group 1/a/1
,andpressENTERtodisconnecttheEVCfromtheLAGgroup.
5. FromtheEVCI n terface Configurationprompt,type
connect men-port gigabit-
ethernet 1/a/1
,andpressENTERtoconnecttheEVCtothenewlycreatedLAGgroup.
6. Type
exit,andpressENTERtoreturntotheGlobalConfigurationprompt.
7. Repeatsteps36asnecessary.
Remove a Link Aggregation Group
Tocreatealinkaggregationgroupandassignphysicalinterfaces,completethefollowing
procedure:
1. FromtheEnableprompt,type
configure terminalandpressENTERtoaccesstheGlo
balConfigurationprompt.
2. FromtheGlobalConfigurationprompt,type
no interface lag-group 1/A/1,and
press
ENTERtodeletethelinkaggregationgroup.
3. FromtheGlobalConfigurationprompt,type
end,andpressENTERtoreturntotheEnable
prompt.
Provision Default Network Interface to SM A, Net 1
Toconfigurethedefaultnetworkinterface,completethefollowingprocedure:
1. FromtheEnableprompt,type
configure terminal,andpressENTERtoaccesstheGlo
balConfigurationprompt.
2. FromtheGlobalConfigurationprompt,type
ethernet default interface
gigabit-ethernet 1/A/1
,andpressENTERtosetthedefaultnetworkinterfacetoSM
A,Net1.
3. FromtheGlobalConfigurationprompt,type
endandpressENTERtoreturntotheEnable
prompt.

Table of Contents

Other manuals for ADTRAN Total Access 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADTRAN Total Access 5000 and is the answer not in the manual?

ADTRAN Total Access 5000 Specifications

Interfaces IconInterfaces
craft interfaceDB-9 RS-232 Electrical Interface (Async)
admin interfaceDB-9 RS-232 DTE Electrical Interface (Async with Modem Control Signals)
network management portDB-9 RS-232 DTE Electrical Interface (Async)
ethernet interface10Bt
external alarm inputs16
Operating Environment IconOperating Environment
operating temperature-40°C to +65°C
storage temperature-40°C to +70°C
relative humidityUp to 95%, non-condensing
Weight and Dimensions IconWeight and Dimensions
height9.25 in.
width0.08 in.
depth9.5 in.
weight0.6 lbs.