Total Access 5000 Business Services Deployment Guide
6-28 65K510DEP08-1A
Disable Unused NetVanta 800 Interfaces
TheNetVanta800declaresalarmsforallunusedinterfaces(DS3,EFM,Ethernet,andPower
Feed).Toclearthesealarmsoncethe800isturnedup,theappropriateinterfacesmustbeshut
down.
Thissectiondetailsthefollowinginformation
•DisabletheDS3interfaces
•DisabletheEthernetinterfaces
•DisabletheGigabitEthernetinterface
•Disablethe
powerfeedalarms
•Clearthealarmlog
Disable the DS1 Interfaces
ForeachunusedDS1portintheEFMBondingGroup,completethefollowing:
NOTE
ThismustbedonetocleartheDS1lossofsignalandEFMnearendsync
alarms.
1. FromtheEnableprompt,type
configure terminal,andpressENTERtoaccesstheGlo
balConfigurationprompt.
2. FromtheGlobalConfigurationprompt,accesstheunusedDS3portʹsconfiguration
promptbytyping
interface t3 1/0/<port>,andpressENTER.
3. FromtheT3InterfaceConfigurationprompt,shuttheDS3portdownbytyping
shutdown,andpressENTER.
4. Repeatsteps2to3fortheremainingunusedDS3ports.
5. FromtheT3InterfaceConfigurationprompt,type
exit,andpressENTERtoreturntothe
GlobalConfigurationprompt.
6. FromtheGlobalConfigurationprompt,type
interface efm-group 1/0/1,andpress
ENTERtoaccesstheEFMBondingGroupConfigurationprompt.
7. RemovetheDS3portfromthebondinggroupbytyping
no link <slot/port>,and
press
ENTER.ForNetVantaproducts,theslotisalwayszero.
8. Repeatstep7toremoveallunusedportsfromtheEFMbondinggroup.
9. Type
end,andpressENTERtoreturntotheEnableprompt.
OnceallunusedDS3interfaceshavebeendisabled,allDS3andEFMbondinggroupalarms
shouldbeclearedinthealarmlog,andtheEFMLEDshouldbelitsolidgreen,ifthereareno
otherissues.Also,thepartialEFMgroupalarmshouldclear.

Table of Contents

Other manuals for ADTRAN Total Access 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADTRAN Total Access 5000 and is the answer not in the manual?

ADTRAN Total Access 5000 Specifications

Interfaces IconInterfaces
craft interfaceDB-9 RS-232 Electrical Interface (Async)
admin interfaceDB-9 RS-232 DTE Electrical Interface (Async with Modem Control Signals)
network management portDB-9 RS-232 DTE Electrical Interface (Async)
ethernet interface10Bt
external alarm inputs16
Operating Environment IconOperating Environment
operating temperature-40°C to +65°C
storage temperature-40°C to +70°C
relative humidityUp to 95%, non-condensing
Weight and Dimensions IconWeight and Dimensions
height9.25 in.
width0.08 in.
depth9.5 in.
weight0.6 lbs.

Related product manuals